Chamber Motion Measurements at the Nsls X-ray Ring

نویسنده

  • L. Solomon
چکیده

Work has been ongoing at the NSLS to improve the orbit stability of the X-Ray Ring by accounting for the thermal motion of the vacuum chamber, which supports the electron beam position monitors (BPMs). In-situ contact measurements of the vacuum chamber motion have been carried out using support stands that have been designed and extensively tested to reduce errors associated with thermal changes in the stands themselves. Using this chamber motion as a correction to the orbit motion measured by the BPMs, the precise location of the radiation beam can be predicted. These predictions are compared with actual radiation beam measurements on the experimental floor, and with predictions based solely on BPM measurements of the electron beam position. This paper reviews this work including stand design and performance, chamber motion measurements, predictions based on these data, and results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small-gap Undulator Experiment on the Nsls X-ray Ring"

We report results of an on-going experiment being carried out in the X13 straight section of the NSLS X-ray Ring which explores the limits of the operation of small-gap undulators. In particular, we discuss measurements of stored electron beam lifetime as a function of the vertical aperture presented by a 4-jaw scraper or a variable-aperture vacuum vessel. At an electron beam current of 300 mA ...

متن کامل

Initial results from an in-vacuum undulator in the NSLS X-ray ring.

A short-period in-vacuum undulator for the NSLS X-ray Ring has been developed in a collaboration between SPring-8 and the NSLS, and has achieved its project design goals during commissioning studies. The device is called IVUN (in-vacuum undulator) and employs magnet arrays (31 periods, with an 11 mm period) developed at SPring-8, while the requisite vacuum chamber and mechanical systems were de...

متن کامل

Development of an in-vacuum minipole undulator.

An in-vacuum minipole (short-period) insertion device has been developed in a collaboration between SPring-8 and the National Synchrotron Light Source (NSLS). The magnetic arrays were constructed by SPring-8 and were installed in a chamber with mechanical parts in the X-ray ring (E = 2.584 GeV) at the NSLS in May 1997. The device is made of permanent magnets with 30.5 periods and a period lengt...

متن کامل

Mechanical Design of NSLS Mini-gap Undulator (MGU)

The mechanical design considerations are discussed with respect to the currently installed X-13 and future X-29 MGU. Comparisons to the previous 2 generations of variable small-gap undulator evolution in the NSLS X-ray ring are made and design improvements noted. The design requirements and mechanical difficulties for holding, positioning and driving the magnetic arrays are explored. Structural...

متن کامل

Nsls In-vacuum Undulators and Mini-beta Straights

We review the work carried out in the X13 R&D Straight Section of the NSLS X-Ray Ring on small gap in-vacuum undulators (IVUNs). Then we discuss: (1) plans to replace the pure permanent magnet undulator in X13 by a hybrid design providing stronger magnetic fields, enhancing the tunability of the device; (2) plans to install hybrid IVUNs in the two RF straights of the X-Ray Ring, increasing the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999