CONCH: A Visual Basic program for interactive processing of ion-microprobe analytical data
نویسنده
چکیده
A Visual Basic program for flexible, interactive processing of ion-microprobe data acquired for quantitative trace element, Al–Mg, Mn–Cr, Fe–Ni and U–Th–Pb geochronology applications is described. Default but editable run-tables enable software identification of secondary ion species analyzed and for characterization of the standard used. Counts obtained for each species may be displayed in plots against analysis time and edited interactively. Count outliers can be automatically identified via a set of editable count-rejection criteria and displayed for assessment. Standard analyses are distinguished from Unknowns by matching of the analysis label with a string specified in the Set-up dialog, and processed separately. A generalized routine writes background-corrected count rates, ratios and uncertainties, plus weighted means and uncertainties for Standards and Unknowns, to a spreadsheet that may be saved as a text-delimited file. Specialized routines process trace-element concentration, Al–Mg, Mn–Cr, Fe–Ni, and Th–U disequilibrium analysis types, and U–Th–Pb isotopic data obtained for zircon, titanite, perovskite, monazite, xenotime and baddeleyite. Correction to measured Pb-isotopic, Pb/U and Pb/Th ratios for the presence of common Pb may be made using measured Pb counts, or the Pb or Pb counts following subtraction from these of the radiogenic component. Common-Pb corrections may be made automatically, using a (user-specified) common-Pb isotopic composition appropriate for that on the sample surface, or for that incorporated within the mineral at the time of its crystallization, depending on whether the Pb count rate determined for the Unknown is substantially higher than the average Pb count rate for all session standards. Pb/U inter-element fractionation corrections are determined using an interactive loge–loge plot of common-Pb corrected Pb/U ratios against any nominated fractionation-sensitive species pair (commonly UO/U) for session standards. Also displayed with this plot are calculated Pb/U and Pb/Th calibration line regression slopes, y-intercepts, calibration uncertainties, standard Pband Pb-corrected Pb/Pb dates and other parameters useful for assessment of the calibration-line data. Calibrated data for Unknowns may be automatically grouped according to calculated date and displayed in color on interactive Wetherill Concordia, Tera–Wasserburg Concordia, Linearized Gaussian (‘‘Probability Paper’’) and Gaussian-summation probability density diagrams. r 2006 Elsevier Ltd. All rights reserved.
منابع مشابه
Imaging biological structures with a proton microprobe
Imaging the morphology of the tissue in vivo and producing the correspondent elemental maps, whether in major, minor, or trace concentrations in real-time can be done using a focused beam of accelerated particles. This can be accomplished using different ion beam techniques simultaneously such as Scanning transmission ion microscopy (STIM), secondary electron imaging (SEI), Rutherford backscatt...
متن کاملI PCLASS - an interactive program for calibrating activated sludge systems
Ipclass – an interactive program for calibrating activated sludge systems – is formulated and demonstrated. The model involves a heuristic screening algorithm for exploring the system's equations structure, analytical computations of the sensitivities of the variables to the model coefficients, analytical computations of the gradients of the objective functions selected for the calibration proc...
متن کاملComparison of Secondary Ion Mass Spectrometry (sims) with Electron Microprobe Analysis (epma) and Other Thin Film Analytical Methods
Different modes of SIMS for thin film analysis and the principle of SIMS will be discussed; this will be followed by a discussion of some features related to instrumentation: types of ion sources and their characteristics; ion microprobe versus ion microscope; special modes of SIMS: sputter neutral mass spectrometry (SNMS) and fast atom bombardment. (FAB). The discussion of analytical features ...
متن کاملThe distribution of trace precious metals in minerals and mineral products
DATA on the distribution of the precious metals (Au, Ag and the platinum=group elements Ru, Rh, Pd, Os, Ir, Pt) are rapidly accumulating as a consequence of the application of microbeam analytical techniques such as the electron microprobe, the proton microprobe, and the ion microprobe. The new data obtained with these techniques build on knowledge accumulated over the last 140 years using bulk...
متن کاملVisual Olap: a New Paradigm for Exploring Multidimensional Aggregates
OLAP (On-Line Analytical Processing) technology provides interactive query-driven analysis of accumulated and consolidated business data for the purpose of decision-making and knowledge extraction. Visualization is increasingly used as the means of gaining insight into huge data volumes of multidimensional data as the former exploits the profound ability of the human vision system to recognize ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computers & Geosciences
دوره 32 شماره
صفحات -
تاریخ انتشار 2006