Estimation of errors in diffraction data measured by CCD area detectors

نویسندگان

  • David Waterman
  • Gwyndaf Evans
چکیده

Current methods for diffraction-spot integration from CCD area detectors typically underestimate the errors in the measured intensities. In an attempt to understand fully and identify correctly the sources of all contributions to these errors, a simulation of a CCD-based area-detector module has been produced to address the problem of correct handling of data from such detectors. Using this simulation, it has been shown how, and by how much, measurement errors are underestimated. A model of the detector statistics is presented and an adapted summation integration routine that takes this into account is shown to result in more realistic error estimates. In addition, the effect of correlations between pixels on two-dimensional profile fitting is demonstrated and the problems surrounding improvements to profile-fitting algorithms are discussed. In practice, this requires knowledge of the expected correlation between pixels in the image.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A laboratory-based Laue X-ray diffraction system for enhanced imaging range and surface grain mapping

Although CCD X-ray detectors can be faster to use, their large-area versions can be much more expensive than similarly sized photographic plate detectors. When indexing X-ray diffraction patterns, large-area detectors can prove very advantageous as they provide more spots, which makes fitting an orientation easier. On the other hand, when looking for single crystals in a polycrystalline sample,...

متن کامل

Research Highlights1

Recently introduced electronic area X-ray detectors (such as CCD based detectors) are having an enormous impact within the experimental x-ray community. The efficiency and ease of data collection has been improved considerably. They are also making practical the implementation of powerful new methodologies in data collection such as fine rotation slicing of crystallography data or multi-wavelen...

متن کامل

Experiences with CCD detectors on a home X-ray source.

Charged-coupled device (CCD) detectors have been widely accepted as detectors for collecting X-ray diffraction images. The CCD detector offers a sensitive detection system well suited for diffraction analysis and, compared with other detectors on the market, a relatively rapid system for read-out of the collected image. The two predominant markets for the CCD detector have been those in which r...

متن کامل

Developing a high-resolution x-ray imager using electron-multiplying (EM) CCDs

Applications at synchrotron facilities such as macromolecular crystallography and high energy X-ray diffraction require high resolution imaging detectors with high dynamic range and large surface area. Current systems can be split into two main categories: hybrid pixel detectors and scintillator-coupled Charge-Coupled Devices (CCDs). Whilst both have limitations, CCD-based systems (coupled to f...

متن کامل

Development of EM-CCD-based X-ray detector for synchrotron applications

Copyright and Moral Rights for the articles on this site are retained by the individual authors and/or other copyright owners. For more information on Open Research Online's data policy on reuse of materials please consult the policies page. We have developed and successfully demonstrated a high speed, low noise camera system for crystallography and X-ray imaging applications. By coupling an EM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2010