Comparison of estimates of left ventricular ejection fraction obtained from gated blood pool imaging, different software packages and cameras

نویسندگان

  • Rachelle Steyn
  • John Boniaszczuk
  • Theodore Geldenhuys
چکیده

OBJECTIVE To determine how two software packages, supplied by Siemens and Hermes, for processing gated blood pool (GBP) studies should be used in our department and whether the use of different cameras for the acquisition of raw data influences the results. METHODS The study had two components. For the first component, 200 studies were acquired on a General Electric (GE) camera and processed three times by three operators using the Siemens and Hermes software packages. For the second part, 200 studies were acquired on two different cameras (GE and Siemens). The matched pairs of raw data were processed by one operator using the Siemens and Hermes software packages. RESULTS The Siemens method consistently gave estimates that were 4.3% higher than the Hermes method (p < 0.001). The differences were not associated with any particular level of left ventricular ejection fraction (LVEF). There was no difference in the estimates of LVEF obtained by the three operators (p = 0.1794). The reproducibility of estimates was good. In 95% of patients, using the Siemens method, the SD of the three estimates of LVEF by operator 1 was ≤ 1.7, operator 2 was ≤ 2.1 and operator 3 was ≤ 1.3. The corresponding values for the Hermes method were ≤ 2.5, ≤ 2.0 and ≤ 2.1. There was no difference in the results of matched pairs of data acquired on different cameras (p = 0.4933) CONCLUSION: Software packages for processing GBP studies are not interchangeable. The report should include the name and version of the software package used. Wherever possible, the same package should be used for serial studies. If this is not possible, the report should include the limits of agreement of the different packages. Data acquisition on different cameras did not influence the results.

منابع مشابه

[Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography].

UNLABELLED Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS Thirty-fiv...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

A new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy. Description, validation and findings in chronic coronary artery disease.

A reproducible, noninvasive technique for determining right ventricular ejection fraction (RVEF) was developed using multiple-gated equilibrium blood pool scintigraphy, which allows serial rapid measurements without reinjection of radioactivity. Studies were obtained using in vitro labeled technetium99m red blood cells, gamma camera and computer. In 20 patients, RVEF determined by multiple-gate...

متن کامل

A New Technique for Assessing Right Ventricular Ejection Fraction Using Rapid Multiple-gated Equilibrium Cardiac Blood Pool Scintigraphy

A reproducible, noninvasive technique for determining right ventricular ejection fraction (RVEF) was developed using multiple-gated equilibrium blood pool scintigraphy, which allows serial rapid measurements without reinjection of radioactivity. Studies were obtained using in vitro labeled technetium99m red blood cells, gamma camera and computer. In 20 patients, RVEF determined by multiple-gate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 25  شماره 

صفحات  -