A Simple And-sensitive Stability-indicating Uhplc-dad Method for the Determination of Cefetamet Pivoxil Hydrochloride.

نویسندگان

  • Piotr Garbacki
  • Judyta Cielecka-Piontek
  • Przemysław Zalewski
  • Irena Oszczapowicz
  • Anna Jelińska
چکیده

A fast and sensitive UHPLC-DAD method was developed and subsequently validated for determination of cefetamet pivoxil hydrochloride in the presence of its degradation products. The chromatographic separation was carried out on a Waters Acquity BEH C18, (2.1 x 100 mm, 1.7 µm) column. The mobile phase was composed of 0.1% formic acid and acetonitrile (40 : 60, v/v) at the flow rate 0.7 mL/min. The detection wavelength was 265 nm and the temperature was 30 °C. Cefetamet pivoxil hydrochloride was susceptible to degradation under the influence of sodium hydroxide, hydrochloric acid and in the conditions of increased temperature and relative humidity. However, it was stable after irradiation, in increased temperature in dry air and in the presence of oxidizing agent. The developed UHPLC-DAD method was linear over the concentration range of 10-240 µg/mL (r2 = 0.9999; n = 12). The obtained RSD values were less than 2%, demonstrating that the described procedure is precise. The accuracy was also confirmed (mean recoveries were 97.79-102.08%). Under applied chromatographic conditions LOD and LOQ values were 2.08 mg/mL and 6.29 mg/mL, respectively. The proposed method was successfully applied in determination of cefetamet pivoxil hydrochloride in aqueous solutions as well as in the solid state.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric Determination of Cefetamet Pivoxil Hydrochloride and Pitavastatin Calcium in Tablet Dosage form

Two simple, rapid, specific and accurate analytical methods for the estimation of cefetamet pivoxil hydrochloride and pitavastatin calcium in bulk drug and in their tablet formulations are described. These methods are based on difference spectrophotometry, wherein the measurement is done at maximum 221 nm and minimum 275 nm for cefetamet whereas at maximum 240 nm and minimum 259 nm for pitavast...

متن کامل

The Development and Validation of a Stability-Indicating UHPLC-DAD Method for Determination of Perindopril l-Arginine in Bulk Substance and Pharmaceutical Dosage Form

A stability-indicating ultra-high-performance liquid chromatography (UHPLC) method with a diode array detector was developed and validated for the determination of cis/trans isomers of perindopril l-arginine in bulk substance and pharmaceutical dosage form. The separation was achieved on a Poroshell 120 Hilic (4.6 × 150 mm, 2.7 µm) column using a mobile phase composed of acetonitrile-0.1 % form...

متن کامل

Development and Validation of a Stability-Indicating Liquid Chromatographic Method for the Determination of Cefditoren Pivoxil in Presence of Degradation Products

A novel stability indicating liquid chromatographic method was developed for the determination of Cefditoren pivoxil in presence of degradation products using Zorbax SB C18 (150 mm × 4.6 mm i.d., 3.5 μm particle size) column with a flow rate 1.0 mL/min (UV detection 210 nm). Linearity was observed over a concentration range 0.1–200 μg/mL with regression equation y = 34809 x + 30603 (R = 0.9994)...

متن کامل

Formulation development and rheological studies of palatable cefetamet pivoxil hydrochloride dry powder suspension

BACKGROUND AND THE PURPOSE OF THE STUDY Because of its intense bitter taste and susceptibility to moisture Cefetamet Pivoxil (CPH) is presently available only in the form of tablet. The aim of this study was to develop taste masked CPH dry powder suspension. METHODS METHODS EMPLOYED FOR FORMULATIONS WERE: a) Film coating of CPH using Eudragit E100 and subsequent adsorption on different carrie...

متن کامل

Development and validation of the stability-indicating LC–UV method for the determination of Cefditoren pivoxil

An isocratic RP-HPLC method was developed for the determination of Cefditoren pivoxil in pharmaceutical formulations using a C-18 column with water-acetonitrile (50:50, v/v) as mobile phase and flow rate 1.2 mL/min (UV detection at 218 nm). Linearity was observed in the concentration range 1.0-250 μg/mL (R2=0.999) with regression equation y=24194x+10749. The forced degradation studies were perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta poloniae pharmaceutica

دوره 73 3  شماره 

صفحات  -

تاریخ انتشار 2016