Measurement of pharyngeal cross-sectional area by finite element analysis.
نویسندگان
چکیده
A noninvasive measurement of pharyngeal cross-sectional area (CSA) during sleep would be advantageous for research studies. We hypothesized that CSA could be calculated from the measured pharyngeal pressure and flow by finite element analysis (FEA). The retropalatal airway was visualized by using a fiber-optic scope to obtain the measured CSA (mCSA). Flow was measured with a pneumotachometer, and pharyngeal pressure was measured with a pressure catheter at the palatal rim. FEA was performed as follows: by using a three-dimensional image of the upper airway, a mesh of finite elements was created. Specialized software was used to allow the simultaneous calculation of velocity and area for each element by using the measured pressure and flow. In the development phase, 677 simultaneous measurements of CSA, pressure, and flow from one subject during non-rapid eye movement (NREM) and rapid eye movement (REM) sleep were entered into the software to determine a series of equations, based on the continuity and momentum equations, that could calculate the CSA (cCSA). In the validation phase, the final equations were used to calculate the CSA from 1,767 simultaneous measurements of pressure and flow obtained during wakefulness, NREM, and REM sleep from 14 subjects. In both phases, mCSA and cCSA were compared by Bland-Altman analysis. For development breaths, the mean difference between mCSA and cCSA was 0.0 mm2 (95% CI, -0.1, 0.1 mm2). For NREM validation breaths, the mean difference between mCSA and cCSA was 1.1 mm2 (95% CI 1.3, 1.5 mm2). Pharyngeal CSA can be accurately calculated from measured pharyngeal pressure and flow by FEA.
منابع مشابه
Innovative Methodology Measurement of pharyngeal cross-sectional area by finite element analysis
Mansour, Khaled F., James A. Rowley, and M. Safwan Badr. Measurement of pharyngeal cross-sectional area by finite element analysis. J Appl Physiol 100: 294–303, 2006. First published September 8, 2005; doi:10.1152/japplphysiol.00364.2005.—A noninvasive measurement of pharyngeal cross-sectional area (CSA) during sleep would be advantageous for research studies. We hypothesized that CSA could be ...
متن کاملPharyngeal Airway: An Analysis Using 2D vs. 3D Images in Different Malocclusions
Introdouction: The aim of this study was to compare information regarding pharyngeal airway sizes in adolescent subjects with different malocclusion classes obtained from lateral cephalograms and 3–dimensional (3D) cone-beam computed tomography (CBCT) scans. Materials and methods: In this prospective cross-sectional study, CBCT scans and lateral cephalograms of 35 subjects, taken with...
متن کاملNonlinear Finite Element Modeling of Different Cross-Sectional Shapes of Slender RC Columns Confined with CFRP Wraps
In the present study, non-linear finite element analyses are carried out on the slender reinforced concrete columns wrapped using CFRP composite with different cross-sectional shapes having the same area. Thickness of the CFRP wraps, concrete compressive strength, corner radius, loading condition, slenderness ratio and column size are the main parameters of this study. According to this, four d...
متن کاملElastic Buckling Analysis of Composite Shells with Elliptical Cross-section under Axial Compression
In the present research, the elastic buckling of composite cross-ply elliptical cylindrical shells under axial compression is studied through finite element approach. The formulation is based on shear deformation theory and the serendipity quadrilateral eight-node element is used to study the elastic behavior of elliptical cylindrical shells. The strain-displacement relations are accurately acc...
متن کاملWhen static meets dynamic: Comparing cone-beam computed tomography and acoustic reflection for upper airway analysis.
INTRODUCTION Upper airway measurement can be important for the diagnosis of breathing disorders. Acoustic reflection (AR) is an accepted tool for studying the airway. Our objective was to investigate the differences between cone-beam computed tomography (CBCT) and AR in calculating airway volumes and areas. METHODS Subjects with prescribed CBCT images as part of their records were also asked ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 100 1 شماره
صفحات -
تاریخ انتشار 2006