Direct determination of trace impurities in niobium pentaoxide solid powder with slurry sampling fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry

نویسندگان

  • Shengqing Li
  • Bin Hu
  • Zucheng Jiang
چکیده

A method of fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry (FETV-ICP-MS) was developed to directly determine the trace impurities in niobium pentaoxide solid powder in which a poly(tetrafluoroethylene) (PTFE) emulsion was used as fluorinating modifier to promote the vaporization of refractory elements from a graphite furnace and to avoid the formation of thermally stable carbides. The solid sample was introduced into the graphite furnace in the form of slurry without any chemical pretreatments. The electrothermal vaporizer device was connected to the ICP system by a laboratory-built interface, and the flow rates of sample carrier gas and auxiliary carrier gas were optimized experimentally. The potentially polyatomic interferences resulting from the pyrolysates of PTFE were evaluated. A new method by stepwise diluting the sample matrix is proposed for investigating the matrix effect and the results showed that no obvious matrix effect was observed with a sample matrix (Nb2O5) concentration of less than 200 mg L . Under the optimal conditions, the absolute limits of detection for FETV-ICP-MS determination of Ta, Ti, Cr, W, Ni, Cu and Mn were in the range of 0.026–1.1 pg. For one analysis run, only 0.002 mg of Nb2O5 sample was required. The proposed method has been applied to determining the trace impurities in Nb2O5 powder, and both the results obtained from the external calibration method and the standard addition method were in a good agreement with those obtained by conventional nebulization ICP-MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Cu, Zn, Cd and Pb in ®sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USSETV-ID-ICP-MS) has been applied to the determination of Cu, Zn, Cd and Pb in several ®sh reference samples. NH4NO3 was added to the sample solution to work as a modi®er. Since the sensitivity of the elements studied in ®sh slurry and aqueous solution was quite different, isot...

متن کامل

Evaluation of solid sampling-electrothermal vaporization- inductively coupled plasma mass spectrometry and solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Cr in various materials using solution- based calibration approaches

M. Resano, E. Garcia-Ruiz, F. Vanhaecke, C. Crespo and M. A. Belarra Laboratory of Analytical Chemistry, Ghent University, Institute for Nuclear Sciences, Proeftuinstraat 86, B-9000 Ghent, Belgium Technological Institute of Aragón, Laboratory of Mechanics and New Materials, Marı́a de una 8, E-50018 Zaragoza, Spain Department of Analytical Chemistry, Faculty of Sciences, University of Zaragoza, P...

متن کامل

Determination of trace rare earth impurities in high-purity cerium oxide by using electrothermal vaporization ICP-AES after HPLC separation with 2-ethylhexyl hydrogen 2-ethylhexylphosphonate resin as the stationary phase

A method is proposed to determine trace rare earth impurities in high-purity CeO2 by HPLC combined with electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). The chromatographic retention behaviours of the matrix (Ce) and rare earth impurities were studied using 2ethylhexyl hydrogen 2-ethylhexylphosphonate (P507) resin as the stationary phase and dil...

متن کامل

Determination of trace impurities in germanium dioxide by ICP-OES, ICP-MS and ETAAS after matrix volatilization: a long-run performance of the method.

High-purity germanium compounds (e.g. germanium dioxide) are used these days in several applications (e.g. germanium-based detectors, semiconductors, fiber-optic systems). Thus, reliable methods for the routine determination of trace element impurities from germanium compounds must be developed. In this study, inductively coupled plasma mass spectrometry, inductively coupled plasma optical emis...

متن کامل

Inorganic trace analysis by mass spectrometry

Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ionimplanted semiconductors...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004