An evaluation of automated blood collection mixers.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES We investigated the mixing capacity of two whole blood (WB) collection mixers. MATERIALS AND METHODS WB was simulated by using a 25% glycerol solution warmed to 35 degrees C. Citrate-phosphate-dextrose (CPD) anticoagulant of a collection system was stained with toluidine blue, and simulated WB was added at 30, 60 or 90 ml/min, respectively (n = 3 per flow speed). The optical density (OD) of 10-ml fractions was measured, and results are expressed as percentage of a well-mixed '100%-sample'. RESULTS CompoGuard showed adequate mixing at all three flow speeds (average ODs 96-103%). HemoLight showed good mixing at 60 and 90 ml/min (ODs from 97 to 101%). At 30 ml/min, mixing appeared suboptimal, but still conformed to our requirements with ODs from 96% to 104%. CONCLUSION Both mixers give sufficient mixing of whole blood with anticoagulant.
منابع مشابه
An Overview on: The Red Blood Cell Histogram
The RBC histogram is an integral part of automated hematology analysis and is now routinely available on all automated cell counters. This histogram and other associated complete blood count (CBC) parameters have been found abnormal in various hematological conditions and may provide major clues in the diagnosis and management of significant red cell disorders. In addition, it is frequently use...
متن کاملDengue with Normal Platelet Count and no Hemoconcentration: Automated Hematogram in Cases with Underlying Thalassemia
Dear Editor, Dengue is an important arbovirus infection. This infection can result in an acute febrile illness. The important hematological abnormalities included hemoconcentration and thrombocytopenia (1). Due to the decreased platelet count, the patient might develop petechiae and hemorrhagic complication. In endemic area, the presumptive diagnosis of dengue is usually derived by the cl...
متن کاملWhat major factors should I consider when selecting an automated batching system?
For example, the feedrate and accuracy of a weighbatching system’s conveyor or feeder doesn’t exclusively determine the system’s overall capacity and accuracy. Other factors that may affect productivity and success include material delivery method, infeed rate, surge vessel capacity, weighing equipment location in relation to mixers, hopper and chute design based on the material’s physical prop...
متن کاملAn Evaluation of Zendeveri (Lifelikeness) in the Architecture of Imam Jome’eh House in Isfahan
The present study intends to shed light on 25 lifelikeness layers in Imam Jome’eh House (Khaneh Emam Jome’eh) in Isfahan as one of the prominent historical monuments dating back to Qajar dynasty. The present study intends to shed light on 25 lifelikeness layers in Imam Jome’eh House (Khaneh Emam Jome’eh) in Isfahan as one of the prominent historical monuments dating back to Qajar dynasty. The l...
متن کاملتفسیر هیستوگرامهای اریتروسیتی بهدستآمده از دستگاههای خودکار هماتولوژی در بیماریهای خونی معمول
Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams) that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC). To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use thos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vox sanguinis
دوره 91 3 شماره
صفحات -
تاریخ انتشار 2006