Giant Right Atrial Mass Following Surgical Aortic Valve Replacement
نویسندگان
چکیده
Figure 1 – Transthoracic echocardiography: giant eco-dense mass occupying the entire right atrium (Panel A) and severely limiting tricuspid valve inflow (Panel B). Atrial wall and visceral pericardium (arrows) A 75-year-old man underwent elective biological aortic valve replacement. Two weeks after surgery, transthoracic echocardiography (TTE) showed a small pericardial effusion. On the following day, the patient suffered from syncope. A repeated TTE revealed a “giant” echo-dense mass (90x80 mm) occupying the entire right atrium and severely limiting tricuspid valve inflow. Although the initial differential diagnosis included the development of an intracavitary process, the rapidly-growing mass with a characteristic echo-lucent layer at its atrial aspect (consistent with the atrial wall and visceral pericardium) (arrows) led to the final diagnosis of a pericardial hematoma mimicking a huge atrial mass. Emergency surgical exploration confirmed the diagnosis. Author contributions Acquisition of data: Bastante T. Analysis and interpretation of the data: Bastante T. Writing of the manuscript: Bastante T, Alfonso F. Critical revision of the manuscript for intellectual content: Bastante T, Alfonso F. Supervision / as the major investigador: Alfonso F.
منابع مشابه
Giant right atrial mass obliterating the right atrium
A73-year-old man with past medical history of mechanical aortic valve replacement, metastatic melanoma of unknown primaries with liver metastasis, presented with progressive shortness of breath and dyspnea on exertion. Transthoracic echocardiography (TTE) showed a large homogenous mass completely occupying the right atrial cavity and extending to and nearly obstructing the inflow area of the tr...
متن کاملDelayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement
Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional ...
متن کاملGiant aneurysm of the left main coronary artery with fistulous communication to the right atrium
The giant coronary artery aneurysm combined with coronary artery fistula is extremely uncommon. In our case, there was a giant aneurysm of the left main coronary artery with fistulous communication to the right atrium, combined with moderate aortic valve regurgitation, which was initially found by transthoracic echocardiogram and subsequently confirmed by the 256-slice multidetector computer to...
متن کاملInterventional repair of pseudoaneurysm of ascending aorta following prosthetic aortic valve replacement.
To cite: Harky A, Khosravi A, Colledge J, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/ bcr-2017-219196 DESCRIPTION Ascending aorta pseudoaneurysm is a high-risk complication post cardiac surgery. Although surgical repair is the conventional method of treatment, it is associated with a high mortality rate of 30% and a very poor prognosis. We report an old ma...
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کامل