Unloading work of breathing during high-frequency oscillatory ventilation: a bench study

نویسندگان

  • Marc van Heerde
  • Karel Roubik
  • Vitek Kopelent
  • Frans B Plötz
  • Dick G Markhorst
چکیده

INTRODUCTION With the 3100B high-frequency oscillatory ventilator (SensorMedics, Yorba Linda, CA, USA), patients' spontaneous breathing efforts result in a high level of imposed work of breathing (WOB). Therefore, spontaneous breathing often has to be suppressed during high-frequency oscillatory ventilation (HFOV). A demand-flow system was designed to reduce imposed WOB. METHODS An external gas flow controller (demand-flow system) accommodates the ventilator fresh gas flow during spontaneous breathing simulation. A control algorithm detects breathing effort and regulates the demand-flow valve. The effectiveness of this system has been evaluated in a bench test. The Campbell diagram and pressure time product (PTP) are used to quantify the imposed workload. RESULTS Using the demand-flow system, imposed WOB is considerably reduced. The demand-flow system reduces inspiratory imposed WOB by 30% to 56% and inspiratory imposed PTP by 38% to 59% compared to continuous fresh gas flow. Expiratory imposed WOB was decreased as well by 12% to 49%. In simulations of shallow to normal breathing for an adult, imposed WOB is 0.5 J l-1 at maximum. Fluctuations in mean airway pressure on account of spontaneous breathing are markedly reduced. CONCLUSION The use of the demand-flow system during HFOV results in a reduction of both imposed WOB and fluctuation in mean airway pressure. The level of imposed WOB was reduced to the physiological range of WOB. Potentially, this makes maintenance of spontaneous breathing during HFOV possible and easier in a clinical setting. Early initiation of HFOV seems more possible with this system and the possibility of weaning of patients directly on a high-frequency oscillatory ventilator is not excluded either.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imposed work of breathing during high-frequency oscillatory ventilation: a bench study

INTRODUCTION The ventilator and the endotracheal tube impose additional workload in mechanically ventilated patients breathing spontaneously. The total work of breathing (WOB) includes elastic and resistive work. In a bench test we assessed the imposed WOB using 3100 A/3100 B SensorMedics high-frequency oscillatory ventilators. METHODS A computer-controlled piston-driven test lung was used to...

متن کامل

Spontaneous breathing during high-frequency oscillatory ventilation improves regional lung characteristics in experimental lung injury.

BACKGROUND Maintenance of spontaneous breathing is advocated in mechanical ventilation. This study evaluates the effect of spontaneous breathing on regional lung characteristics during high-frequency oscillatory (HFO) ventilation in an animal model of mild lung injury. METHODS Lung injury was induced by lavage with normal saline in eight pigs (weight range 47-64 kg). HFO ventilation was appli...

متن کامل

Respiratory muscle activity and patient–ventilator asynchrony during different settings of noninvasive ventilation in stable hypercapnic COPD: does high inspiratory pressure lead to respiratory muscle unloading?

INTRODUCTION High-intensity noninvasive ventilation (NIV) has been shown to improve outcomes in stable chronic obstructive pulmonary disease patients. However, there is insufficient knowledge about whether with this more controlled ventilatory mode optimal respiratory muscle unloading is provided without an increase in patient-ventilator asynchrony (PVA). PATIENTS AND METHODS Ten chronic obst...

متن کامل

Exercise-induced respiratory muscle work: effects on blood flow, fatigue and performance.

In healthy subjects heavy intensity endurance exercise places substantial demands on the respiratory muscles as breathing frequency, ventilation and the work of breathing rise over time. In the highly trained subject working at high absolute work rates the ventilatory demand often causes varying degrees of expiratory flow limitation, sometimes accompanied by lung hyperinflation and therefore in...

متن کامل

The Effect of Compliance Changes on Delivered Volumes in an Adult Patient Ventilated with High Frequency Oscillatory Ventilation: A Bench Model

The Effect of Compliance Changes on Delivered Tidal Volumes and Amplitude in an Adult Patient Ventilated with High Frequency Oscillatory Ventilation: A Bench Model By John A. England Clinical concerns exist regarding the delivered tidal volume (Vt) during highfrequency oscillatory ventilation (HFOV). HFOV is increasingly being used as a lung protective mode of ventilation for patients with Adul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2006