Topical Nasal Anesthesia in Flexible Bronchoscopy – A Cross-Over Comparison between Two Devices

نویسندگان

  • Thomas Fuehner
  • Jan Fuge
  • Meike Jungen
  • Anna Buck
  • Hendrik Suhling
  • Tobias Welte
  • Jens Gottlieb
  • Mark Greer
چکیده

INTRODUCTION Topical airway anesthesia is known to improve tolerance and patient satisfaction during flexible bronchoscopy (FB). Lidocaine is commonly used, delivered as an atomized spray. The current study assesses safety and patient satisfaction for nasal anesthesia of a new atomization device during outpatient bronchoscopy in lung transplant recipients. METHODS Using a prospective, non-blinded, cross-over design, patients enrolled between 01-10-2014 and 24-11-2014 received 2% lidocaine using the standard reusable nasal atomizer (CRNA). Those enrolled between 25-11-2014 and 30-01-2015, received a disposable intranasal mucosal atomization device (DIMAD). After each procedure, the treating physician, their assistant and the patient independently rated side-effects and satisfaction, basing their responses on visual analogue scales (VAS). At their next scheduled bronchoscopy during the study period, patients then received the alternative atomizer. Written consent was obtained prior to the first bronchoscopy, and the study approved by the institutional ethics committee. RESULTS Of the 252 patients enrolled between 01-10-2014 and 30-01-2015, 80 (32%) received both atomizers. Physicians reported better efficacy (p = 0.001) and fewer side effects (p< = 0.001) for DIMAD in patients exposed to both procedures. Among patients with one visit, physicians and their assistants reported improved efficacy (p = 0.018, p = 0.002) and fewer side effects (p< = 0.001, p = 0.029) for the disposable atomizer, whereas patients reported no difference in efficacy or side effects (p = 0.72 and p = 0.20). No severe adverse events were noted. The cost of the reusable device was 4.08€ per procedure, compared to 3.70€ for the disposable device. DISCUSSION Topical nasal anesthesia via a disposable intranasal mucosal atomization device (DIMAD) offers comparable safety and patient comfort, compared to conventional reusable nasal atomizers (CRNA) in lung transplant recipients. Procedural costs were reduced by 0.34€ per procedure. TRIAL REGISTRATION clinicaltrials.gov NCT02237651.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Total Intravenous Anesthesia (TIVA) with Inhalation Anesthesia in Pediatric Bronchoscopy

Background: Because of airway stimulations during the bronchoscopy and lack of direct access to the airway, preferred method of anesthesia for rigid bronchoscopy is already controversial. In this study we compared inhalation anesthesia with total intravenous anesthesia (TIVA) for rigid bronchoscopy. Method and Materials: 30 patients aged 2-6 years were chosen divided on two same groups. Anesthe...

متن کامل

Comparison of Anesthetic Techniques on Outcomes of Pediatric Rigid Bronchoscopy for Foreign Body Removal

Background Although both methods of spontaneous respiration and controlled ventilation during anesthesia are safe and effective for managing children with foreign body aspiration, there is no consensus from the literature as to which technique is optimal. This study aimed to determine the outcomes of anesthetic techniques in pediatric rigid bronchoscopy for foreign body removal. Materials and M...

متن کامل

Comparison of Effect of Two Treatment Methods: Oxygen Therapy with Face Mask and Nasal Catheter on Nausea and Vomiting and Comfort in Cesarean section under Spinal Anesthesia

Background: Receiving Oxygen during Cesarean section under spinal anesthesia can be a good way to prevent from nausea and vomiting of mothers and hypoxemia of fetus. This study aimed to compare the effect of two treatment methods of Oxygen therapy with facemask and nasal catheter on vomiting and nausea and patient's comfort during Cesarean section under spinal anesthesia. Methods: This clini...

متن کامل

A survey of flexible bronchoscopy practices in India: The Indian bronchoscopy survey (2017)

Background There is a lack of contemporaneous data on the practices of flexible bronchoscopy in India. Aim The aim of the study was to study the prevalent practices of flexible bronchoscopy across India. Methods The "Indian Bronchoscopy Survey" was a 98-question, online survey structured into the following sections: general information, patient preparation and monitoring, sedation and topic...

متن کامل

Risk factors of hypoxia during flexible bronchoscopy use in infants.

A Japanese, Shigeto Ikeda, invented the flexible bronchoscope (FB) in 1966; the FB was introduced into clinical practice due to its diagnostic accuracy, safety, and ease of use. Currently, the FB is one of the most important tools for diagnosis and treatment of pulmonary diseases in child and infants. The tendency to subdivide bronchoscopes into adult and pediatric categories depending on their...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016