Importance of body surface potential field representation fidelity: analysis of beat-to-beat repolarization measurements.
نویسندگان
چکیده
OBJECTIVE According to previous studies, the complex substrate of malignant arrhythmias needs a detailed spatio-temporal noninvasive characterization of low-amplitude dynamic changes in beat-to-beat cardiac repolarization. METHODS Body surface potential map (BSPM) records were taken on 14 healthy male and female subjects (age 20-80 years) and on 6 ventricular arrhythmia patients, 4 of them with implanted cardioverter defibrillators (ICD). Records were taken continuously, for 5 minutes, in resting, supine position. Beat-to-beat QRST integral maps, Karhunen-Loéve coefficient time-series (KLi, i=1-12), RR and nondipolarity index (NDI) time-series were computed. RESULTS The first order statistical properties of the spatio-temporal variability of subsequent QRST integral maps were characterized by the box and whiskers plot of their KLi components. The SD2/M2 (KLi amplitude variance/mean signal energy) values of the QRST integral maps in the normal group ranged between 0.0057 and 0.008 (i.e. 0.075=or<SD/M=or<0.089). In ICD patients SD2/M2 values went up to 0.021-0.069 (i.e: 0.14=or<SD/M=or<0.26). Autocorrelation functions revealed that while in normal subjects only 5-20% of the total power had white noise character, the rest was bandwidth-limited noise. In ICD patients the weight of white noise component increased considerably. The higher the SD/M relative KL variability, the higher and more frequent NDI spikes were. CONCLUSIONS Beat-to-beat dynamics of white noise components of high resolution BSPMs are able to stratify arrhythmia vulnerability. The temporal distribution of extreme NDI spike formations is random; the frequency is associated with the relative KL component noise levels.
منابع مشابه
Spontaneous variability and reactive postural beat-to-beat changes of integral ECG body surface potential maps.
There is virtually no information on spontaneous variability of ECG body surface potential maps (BSPMs) and on dynamics of their reactive changes in healthy subjects. This study evaluated quantitatively the depolarization (QRS) and repolarization (QRST) parameters derived from the respective integral BSPMs, constructed beat-to-beat, from continual body surface ECG records in 9 healthy men resti...
متن کاملDynamic Beat-to-Beat Changes of the Cardiac Electric Field in Response to Situations with Increased Sympathetic Activity
Only a few studies – evaluating body surface potential maps (BSPMs) from a selected single beat, or from an average constructed of some heart beats have dealt with reactive changes of BSPMs in response to different physiological conditions. Our aim was to analyse the previously unexplored dynamic beat-to-beat pattern of the reactive changes in the ventricular depolarization and repolarization, ...
متن کاملBeat-to-beat interplay of heart rate, ventricular depolarization, and repolarization.
To improve malignant arrhythmia risk stratification, the causal and random components of spatiotemporal dynamics of heart rate (RR distances), ventricular depolarization sequence, and repolarization disparity were studied based on body surface potential map records taken for 5 minutes, in resting, supine position on 14 healthy subjects (age range, 20-65 years) and on 6 arrhythmia patients (age ...
متن کاملA review of beat-to-beat vectorcardiographic (VCG) parameters for analyzing repolarization variability in ECG signals.
Elevated ventricular repolarization lability is believed to be linked to the risk of ventricular tachycardia/ventricular fibrillation. However, ventricular repolarization is a complex electrical phenomenon, and abnormalities in ventricular repolarization are not completely understood. To evaluate repolarization lability, vectorcardiography (VCG) is an alternative approach where the electrocardi...
متن کاملComputer modelling of beat-to-beat repolarization heterogeneity in human cardiac ventricles
Based on our numerical heart and chest model with stochastically modifiable action potential duration (APD) parameters, the consequences of diminished subepicardial cell-to-cell coupling were studied on beat-to-beat repolarization heterogeneity. Pathological action potential durations and transmural gradient (TG) mean values (M) were assumed in the apical segment of the five-layer heart model, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology
دوره 7 Suppl 1 شماره
صفحات -
تاریخ انتشار 2007