Evaluation of foraminal transportation during foraminal enlargement with different instrumentation systems
نویسندگان
چکیده
Aim: To evaluate the foraminal transportation during foraminal enlargement after manual instrumentation with stainless steel files, preparation with the Mtwo system and Reciproc R25 file. Methods: Thirty roots were selected, divided in three groups and prepared in accordance with the different instrumentation systems: Hand Files (HF); Mtwo system (MS); and Reciproc system (RS). All groups were prepared with the instrumentation level 1 mm beyond the apex. Photomicrographs were performed using scanning electron microscopy, to record the foraminal anatomy before and after instrumentation. Data were analyzed using ANOVA followed by Tukey’s test with a significance level of 5%. Results: The group instrumented with hand files showed higher foraminal transportation when compared to the Mtwo and Reciproc groups (p<0.05). Reciproc group showed lower transportation when compared to the Mtwo group (p<0.05). Conclusions: The stainless steel files caused significant foraminal transportation, while Reciproc system showed safe apical preparation, with little transportation.
منابع مشابه
Novel Foraminal Expansion Technique
The technique we describe was developed for cervical foraminal stenosis for cases in which a keyhole foraminotomy would not be effective. Many cervical stenosis cases are so severe that keyhole foraminotomy is not successful. However, the technique outlined in this study provides adequate enlargement of an entire cervical foraminal diameter. This study reports on a novel foraminal expansion tec...
متن کاملDebris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires
To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF. The AF of 120 root canals in 60 mesial roots o...
متن کاملMagnetic resonance imaging of normal lumbar intervertebral foraminal height.
OBJECTIVE To study the pattern and changes of lumbar intervertebral foraminal heights in an asymptomatic Jordanian sample relative to age, sex, level, and correlate values with midpoint vertebral and disc heights. METHODS One hundred and fifty-three patients (87 male and 66 female) were selected during the study period. The study was carried out at the Jordan University Hospital, Amman, Jorda...
متن کاملPredicting Unilateral Postlaminectomy C5 Palsy by Measuring C5 Exit Foramen Area on Preoperative Computed Tomography
Background. Postoperative C5 motor palsy is known as a common complication not only after cervical laminectomy but also after anterior discectomy. There is no consensus to verify any of the proposed mechanisms of C5 palsy following posterior cervical decompression. The authors of this article have found that C5 palsy is more common among patients with smaller C5 root exit foramen area. The purp...
متن کاملEffects of Anterior Interbody Cages on Lumbar Foraminal Dimensions
INTRODUCTION: Anterior lumbar interbody fusion (ALIF) using threaded cages has been shown to reduce segmental motion and restore the disc space. The effectiveness of these stand-alone cages in restoration and maintenance of intervertebral foramens has received little attention. Foraminal height reduces an average of 6.5 mm following disc removal, and interbody cages may indirectly increase and ...
متن کامل