Must radiation dose for CT of the maxilla and mandible be higher than that for conventional panoramic radiography?

نویسندگان

  • C G Diederichs
  • W G Engelke
  • B Richter
  • K P Hermann
  • J W Oestmann
چکیده

We evaluated the feasibility of performing preoperative spiral CT of the maxilla and mandible with a radiation dose similar to that used for conventional panoramic radiography. The skin entrance doses of radiation used for spiral CT (collimation, 1 mm; pitch, 2; tube voltage, 80 kV; tube current, 40 mA) and for panoramic radiography (75 kV, 8 mA, 15 seconds) were measured in one patient by using thermoluminescent dosimeter chips. Results were 0.56 +/- 0.06 mGy for CT and 0.59 +/- 0.04 mGy for radiography. Image quality was adequate for preoperative implant planning. Spiral CT of the mandible and maxilla may therefore be feasible with a radiation dose of similar magnitude as that used for conventional panoramic radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی دوز جذب اشعه در پرتونگاری های مورد نیاز ایمپلنت های دندانی

Concern for adverse effects must accompany any use of ionizing radiation. Such concern for the expanded use of CT scanning, conventional tomography and panoramic in dental implant radiology can be expressed by the establishment of absorbed radiation dose for critical tissues (resulting from these radiographic procedures). Potential patient benefit should be weighted against the risk and other d...

متن کامل

بررسی میزان بزرگنمایی عمودی رادیوگرافی پانورامیک در مقایسه با CBCT به تفکیک محل آناتومیک

Background: Currently, dental implant is one of the most modern approaches to teeth replacement. Panoramic radiography is considered as the prerequisite for implant therapy. The purpose of the present study was to investigate the vertical magnification of digital panoramic images in various anatomic parts of the mandible. Method: A total of 30 patients referred to Sajjad Radiography Center for...

متن کامل

تعیین دقت رادیوگرافی پانورامیک در تعیین زوایای مزیودیستال دندان‌ها

Introduction: Nowadays, the use of panoramic radiographs for evaluation of uprighting and root parallelism, after the closure of spaces and before the debanding of fixed appliances, often been accepted, and the use of radiography to evaluate the results at the end of orthodontic treatment is discussed.It is not clear whether panoramic radiography reflects the exact mesiodistal position of the ...

متن کامل

بررسی مقایسه‌ای دوز جذبی اشعه در اندام‌های هدف درتصویربرداری از ناحیه فک و صورت با تکنیک‌های پانورامیک، توموگرافی خطی، CBCT و CT پزشکی

Background and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT) and computed tomography (CT).Materials and Methods: Thermoluminescent dosimeters (TLD) were implanted in 14 sites of RANDO phantom to measu...

متن کامل

Evaluation of radiation-induced cancer risk to patients undergoing intra-oral and panoramic dental radiographies using experimental measurements and Monte Carlo calculations

Background: Radiation doses associated with the conventional dental radiographies are relatively low, but their number is high. Therefore, justification is necessary to ensure that radiation doses to patients, particularly children, are kept as low as reasonably achievable. Materials and Methods: The exposure factors applied for real patients in four age groups (5, 10, 15-year-old and adult) we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 17 9  شماره 

صفحات  -

تاریخ انتشار 1996