Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study

نویسندگان

  • Lu Cao
  • Qian Chen
  • Li-Bo Jiang
  • Xiao-Fan Yin
  • Chong Bian
  • Hui-Ren Wang
  • Yi-Qun Ma
  • Xiang-Qian Li
  • Xi-Lei Li
  • Jian Dong
چکیده

STUDY DESIGN This is an experimental animal study. OBJECTIVE The objective of this study was to compare an anterior cervical discectomy and interbody fusion of a novel polylactide/nano-sized β-tricalcium phosphate (PLA/nβ-TCP) bioabsorbable self-retaining cervical fusion cage (BCFC) with an autologous bone graft and polyetheretherketone (PEEK) cages. BACKGROUND Although PLA cervical cages have potential advantages compared with traditional materials, they are not currently routinely used in spine surgery because of undesirable effects such as the lack of osteoconductivity and osteolysis around the implant. This study involved the manufacturing of a bioabsorbable cage from PLA/nβ-TCP that was then used as a device for anterior cervical discectomy and fusion (ACDF) on a goat cervical spine fusion model. MATERIALS AND METHODS Eighteen goats underwent C3/C4 discectomy and were randomly divided into three groups based on the following methods: Group A (n=6), an autologous bone graft; Group B (n=6), PEEK cage filled with an autologous graft; and Group C (n=6), BCFC filled with an autologous iliac bone. Radiography was performed preoperatively and postoperatively and at 1, 4, 8, and 12 weeks after the operation. Disc space height (DSH) was measured at the same time. After 12 weeks, the fused segments were harvested and evaluated with functional radiographic views, biomechanical testing, and histological analyses. RESULTS Over a 12-week period, the BCFC and PEEK cage groups exhibited significantly higher DSH values than the bone graft group. Additionally, the BCFC group yielded a significantly lower range of motion in axial rotation than both the autologous bone graft and PEEK cage groups. A histologic evaluation revealed an increased intervertebral bone volume/total volume ratio and better interbody fusion in the BCFC group than in the other groups. CONCLUSION The BCFC device exhibited better results than the autologous bone graft and PEEK cages in single-level ACDF models in vivo. This device may be a potential alternative to the current PEEK cages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical stability of a bioabsorbable self-retaining polylactic acid/nano-sized β-tricalcium phosphate cervical spine interbody fusion device in single-level anterior cervical discectomy and fusion sheep models

PURPOSE The aim of this study was to investigate the biomechanical stability provided by a novel, polylactic acid/nano-sized, β-tricalcium phosphate, bioabsorbable, self-retaining cervical fusion cage (BCFC). METHODS Quasistatic nonconstraining torques (maximum 1.5 NM) induced flexion, extension, lateral bending (±1.5 NM), and axial rotation (±1.5 NM) on 32 sheep cervical spines (C2-C5). The ...

متن کامل

Osteoinductive activity of ErhBMP-2 after anterior cervical diskectomy and fusion with a ß-TCP interbody cage in a goat model.

Bone morphogenetic protein (BMP)-2 induces bone and cartilage tissue formation. Large amounts of BMP-2 are difficult to purify or to produce in vitro using eukaryotic cells. The goal of the present study was to assess the clinical use of Escherichia coli-derived recombinant human BMP-2 (ErhBMP-2) on bone fusion after cervical and lumbar spine surgery in a goat model, compared with the standard ...

متن کامل

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

Preliminary results in anterior cervical discectomy and fusion with an experimental bioabsorbable cage – clinical and radiological findings in an ovine animal model

BACKGROUND Bioabsorbable implants are not widely used in spine surgery. This study investigated the clinical and radiological findings after anterior cervical discectomy and fusion (ACDF) in an ovine animal model with an experimental bioabsorbable cage consisting of magnesium and polymer (poly-ϵ-caprolactone, PCL) in comparison to a tricortical bone graft as the gold standard procedure. MATER...

متن کامل

Early findings in a pilot study of anterior cervical interbody fusion in which recombinant human bone morphogenetic protein-2 was used with poly(L-lactide-co-D,L-lactide) bioabsorbable implants.

OBJECT The goal of this study was to assess the efficacy of bioabsorbable interbody spacers in cervical spine fusion. METHODS The authors report on a prospective examination of 20 patients with degenerative cervical disc disease who underwent anterior cervical fusion at 28 total levels. The authors used Infuse bone graft (that is, recombinant human bone morphogenetic protein-2 applied to an a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017