Trajectory-based Deformation Correction in Ultrasound Images

نویسندگان

  • Brian W. Anthony
  • Matthew W. Gilbertson
  • Shih-Yu Sun
چکیده

Tissue deformation in ultrasound imaging poses a challenge to the development of many image registration techniques, including multimodal image fusion, multi-angle compound image and freehand three-dimensional ultrasound. Although deformation correction methods are desired to provide images of uncompressed tissue structure, they have not been well-studied. A novel trajectory-based method to correct a wide range of tissue deformation in ultrasound imaging was developed. In order to characterize tissue deformation under different contact forces, a force sensor provides contact force measurement. Template based image-flow techniques were applied to RF A-lines under different contact forces. A two-dimensional displacement trajectory field was constructed, where pixel coordinates in each scan were plotted against the corresponding contact force. Nonlinear extrapolation algorithms are applied to each trajectory to relocate the corresponding pixel to where it would have been had there been no contact, thereby correcting tissue deformation in the images. This method was validated by using a combination of FEM deformation and ultrasound simulation. It was shown that deformation of the simulated pathological tissue could be corrected. Furthermore, nonlinear polynomial regression was found to give better estimates, than linear regression, when large deformation was present. Estimation accuracy was not improved significantly for a polynomial regression larger than second order.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deformation Correction in Ultrasound Imaging

Tissue deformation in ultrasound imaging is an inevitable phenomenon and poses challenges to the development of many techniques related to ultrasound image registration, including multimodal image fusion, freehand three-dimensional ultrasound, and quantitative measurement of tissue geometry. In this thesis, a novel trajectory-based method to correct tissue deformation in ultrasound B-mode imagi...

متن کامل

Validation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound: preliminary method and results

Soft tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface based metrics and sub-surface validation has largely been perfor...

متن کامل

Evaluation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound.

Soft-tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface-based metrics, and subsurface validation has largely been perfor...

متن کامل

Augmented Reality Enhanced Image-Guided Surgery System Using CT and Ultrasound Registration for Brain-Shift Estimation

In neurosurgery, brain shift, usually caused by the gravity or the changes of intra-cranial pressure, is the main factor to affect the accuracy of tumor removal. To deal with this problem, an imageguided surgery system which corrects the brain shift from the preoperative CT images by using intra-operative ultrasound images is presented. First, with reconstructing 2-D free-hand ultrasound images...

متن کامل

Clinical validation of vessel-based registration for correction of brain-shift

The displacement and deformation of brain tissue is a major source of error in image-guided neurosurgery systems. We have designed and implemented a method to detect and correct brain shift using pre-operative MR images and intraoperative Doppler ultrasound data and present its validation with both real and simulated data. The algorithm uses segmented vessels from both modalities, and estimates...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010