Complete myelography with metrizamide.

نویسندگان

  • A J Fox
  • F Vinuela
  • G Debrun
چکیده

Thorough myelography of the entire spinal cord including the foramen magnum region can be accomplished consistently and promptly after metrizamide injection via lumbar or lateral cervical puncture. When lumbar puncture is used the patient's torso is oblique, but the neck is prone and straight and the table is tilted 20 degrees head-down to allow direct cervical filling with contrast material. Each region is filmed in several projections, the patient being turned gently from the prone cervical to the supine thoracic position. Of 100 cases without block studied in this way, all had adequate cervical and foramen magnum films. In only five was the contrast material too dilute to show the edges of the spinal cord well and the subarachnoid sac adequately in the thoracic region. In 29 patients, there were mild side effects not requiring medication, while 20 had side effects of a more moderate to severe nature. No seizures were encountered. Metrizamide proved a convenient, efficient, and acceptable contrast medium for myelography when a study of the entire spinal cord is indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metrizamide myelography for disk disease: continuing need for epidural venography.

Metrizamide is largely replacing iophendylate (Pantopaque) for routine lumbar myelography. Better visualization of the nerve root sheaths should make metrizamide myelography more sensitive in detecting laterally herniated disks, such that epidural venography might be required less often. However, that expectation has not been realized. In over 800 consecutive myelograms, one-half obtained with ...

متن کامل

Iohexol vs. metrizamide: study of efficacy and morbidity in cervical myelography.

A double-blind study was conducted in 60 patients undergoing either cervical or more complete myelography via C1-C2 puncture. Patients received either iohexol or metrizamide at a 300 mg l/ml concentration. The contrast media were equally efficacious in the production of high-quality radiographs and CT scans. However, the incidence of adverse reactions differed markedly. Of patients receiving me...

متن کامل

Transient motor aphasia following metrizamide myelography.

Metrizamide, a water-soluble iodinated contrast agent for myelography, has been widely used in the United States for more than 4 years . Although acute generalized encephalopathy with confusion has been recog nized as a complication of metrizamide myelography, aphasia, with the connotation of focality that it entails, has seldom been reported [1, 2]. We describe two patients with a transient mo...

متن کامل

Discrepancy between metrizamide CT and myelography in diagnosis of cervical disk protrusions.

With the advent of the relatively safe water-soluble contrast medium metrizamide, cervical myelography followed by metrizamide computed tomography (CT) can be performed easily. Sixteen patients with cervical disk protrusions (eight central and eight posterolateral) were studied by both procedures to evaluate the diagnostic value of each. In 75% of the posterolateral disk protrusions, myelograph...

متن کامل

Conventional and CT metrizamide myelography in Arnold-Chiari I malformation and syringomyelia.

Four normal controls and 26 cases of Arnold-Chiari I malformations and/or syringomyelia were reviewed. The pathologic cases included five isolated Arnold-Chiari I malformations, nine communicating syringomyelia, five idiopathic syringomyelia, four posttraumatic syringomyelia, one syringomyelia with hemangioblastoma, and two postshunt syringomyelia. The objectives of this study were to compare t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 1981