Validation of respiratory inductive plethysmography in patients with pulmonary disease.
نویسندگان
چکیده
The assumption that the respiratory system behaves with 2 df of motion in healthy persons allows calibration of respiratory inductive plethysmography (RIP) with spirometry (SP). To ascertain whether RIP could be calibrated by the same assumption in patients with lung disease, even though at least 3 df of motion are visualized (ie, upper and lower rib cage and upper and lower abdomen move out of phase), RIP was calibrated by a two-position calibration procedure and validated satisfactorily by simultaneous SP in the erect, semirecumbent, supine, and lateral decubitus positions. In lung disease, the contribution to tidal volume of regions moving independently of the combined rib cage and abdominal movements either is small or remains relatively constant with change of body posture. For clinical monitoring of the resting breathing pattern where patient movements cannot be restricted, respiratory inductive plethysmography can serve as a reliable semiquantitative, noninvasive ventilatory monitoring device.
منابع مشابه
Respiratory Monitoring: Advantages of Inductive Plethysmography over Impedance Pneumography
Inductive plethysmography and impedance pneumography are two non-invasive technologies for measuring respiratory function. The following report describes the advantages of inductive plethysmography, which include greater accuracy and sensitivity; the ability to assess thoracoabdominal coordination; and the minimization of motion artifact. Together, these properties make inductive plethysmograph...
متن کاملDetection of inspiratory flow limitation during sleep by computer assisted respiratory inductive plethysmography.
The potential of respiratory inductive plethysmography (RIP) to detect inspiratory flow limitation during sleep was investigated. Sixteen sleep apnoea patients underwent polysomnography. Airflow by a flowmeter attached to a nasal mask, oesophageal and mask pressure were recorded along with calibrated RIP. Presence of inspiratory flow limitation was defined by constant or decreasing flow without...
متن کاملEvaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.
STUDY OBJECTIVE To assess the accuracy of the respiratory inductive plethysmography in the measurement of PEEP-induced changes in end-expiratory lung volume during mechanical ventilation and its accuracy and stability in the measurement of ventilation during controlled mechanical ventilation and spontaneous breathing. DESIGN An open comparison between two methods using a criterion standard. E...
متن کاملThe Evaluation of Pulmonary Function Tests in Patients with Polycystic Ovary Syndrome
Introduction: Recently a relation between female sex hormones and severity of asthma symptoms has been proposed. As a common endocrine dysfunction, polycystic ovary syndrome (PCOS) could significantly influence the level of sex hormones in PCOS patients. Regarding the possible role of sex hormones in airway physiology, the present study was conducted to survey the effects of PCOS on pulmonary f...
متن کاملاثر مکمل یاری ویتامین های D، C و E بر نتایج تست های اسپیرومتری و پلتیسموگرافی در بزرگسالان مبتلا به فیبروز ریوی
Background: Idiopathic pulmonary fibrosis is one of the most important chronic respiratory diseases. One of the causes of its occurrence and exacerbation is imbalance in the antioxidant and inflammatory systems. The aim of this study was to evaluate the effect of supplementation of these vitamins on functional lung tests in adults with pulmonary fibrosis. Methods: 33 patients participated in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 83 4 شماره
صفحات -
تاریخ انتشار 1983