Cephalad angulation of epidural needle insertion may be an important factor for safe epidural space approach: a mathematical model.

نویسندگان

  • Satoki Inoue
  • Masahiko Kawaguchi
  • Hitoshi Furuya
چکیده

BACKGROUND AND OBJECTIVES Epidural approach angle is one of the determining factors for needle traveling length to reach the epidural space. Likewise, the margin of safety against accidental dural puncture should be affected by epidural approach angle because the space available for epidural needle tip movement in the epidural space is depending on the inserting angle to the epidural space. The purpose of this study is to conjecture the effect of the angle formed with the skin and an epidural needle on the margin of safety against accidental dural puncture using a mathematical model. CASE REPORT Suppose that the width of the epidural space is A mm and that the force advancing the epidural catheter is Ckgf and the diameter of the catheter is D mm. In this situation, assuming that the cephalad angle with the midline approach formed with the skin and an epidural needle is θ, the following parameters can be determined: the available distance for the needle tip in the epidural space = A/sinθmm; cephalad advancing force of catheter = C*cosθkgf; and the pressure at the site of dura matter where the epidural catheter is pushing = 400*C*sinθ.πD(-2)kgf.cm(-2). The longer the distance available for the needle tip, the larger the margin of safety for dura injury by the epidural needle. It is supposed that θ should be set smaller to make the margin of safety larger. Likewise, smaller θ could decrease the pushing pressure and more effectively create a distinct cephalad advancing force. CONCLUSIONS Acute cephalad angulation should be considered to increase the margin of safety for epidural approach and catheterization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cephalad angulation of epidural needle insertion may be a major factor for epidural space safe approach: a mathematical model.

Regarding the mathematical study of Inoue et al. 1, it is appropriate to mention the study by Cheng (Apud Collins) 2 published more than half a century ago in which the width of the circular epidural space (EP) and thickness of the dura mater (DM) were measured. According to Cheng 2, the axial width of EP at L2-L3 is 6 mm and if the puncture is 30 degrees to the skin, the puncture safety margin...

متن کامل

بررسی درد محل تزریق، کمردرد و رضایت بیماران از تکنیک اپیدورال در دو روش مدین و پارامدین

Background and purpose: Median epidural block is often done with some difficulty due to pain, ossification of interspinous ligament and improper positioning of patient. Ïn addition, back pain is common with median approach, that may be due to puncture of ligaments on the line of epidural needle passage. Ïn paramedian approach needle dose not pass through ligaments, so back pain can be theoret...

متن کامل

Acute Epidural Hematoma after Ventriculoperitoneal Shunt Insertion: a Case Report

Background & Importance: Acute epidural hematoma is a very rare complication of ventriculoperitoneal shunt insertion. The insertion of a ventriculoperitoneal shunt can cause sudden decompression of the brain, subsequent to which epidural hematoma occurs due to CSF drainage. To our knowledge, there are only a few cases of acute epidural hematoma in the literature which required acute e...

متن کامل

بی‌حسی کامل نخاعی در بیمار مبتلا به آکندروپلازی: گزارش موردی

Background: Total spinal anesthesia is a complication of lumbar epidural anesthesia following undiagnosed subarachnoid or subdural injection of local anesthetic. Although many achondroplastic dwarfs have a normal spine, catheter insertion may be more problematic with a narrow epidural space making a subarachnoid tap more probable.  Other malformations associated with achondroplasia, such as pro...

متن کامل

Description of Optimal Angle of Needle Insertion For L5 Transforaminal Epidural Injection Leads to Complications.

Ra and Min (1) painstakingly have described the optimal angle of needle insertion for fluoroscopically guided transforaminal epidural injection of L5. Unfortunately, this potentially increases further complications related to lumbar transforaminal epidural injections with the safe triangle approach (2).Clearly, the literature undeniably shows that the safe triangle approach may not be safe and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 61 6  شماره 

صفحات  -

تاریخ انتشار 2011