Impact of the Quality of Bowel Cleansing on the Efficacy of Colonic Cancer Screening: A Prospective, Randomized, Blinded Study

نویسندگان

  • Jürgen Pohl
  • Marc Halphen
  • Hans Rudolf Kloess
  • Wolfgang Fischbach
چکیده

OBJECTIVES Efficacy of two low volume bowel cleansing preparations, polyethylene glycol plus ascorbate (PEG + Asc) and sodium picosulfate/magnesium citrate (NaPic/MgCit), were compared for polyp and adenoma detection rate (PDR and ADR) and overall cleansing ability. Primary endpoint was PDR (the number of patients with ≥ 1 polypoid or flat lesion recorded by the colonoscopist). METHODS Diagnostic, surveillance or screening colonoscopy patients were enrolled into this investigator-blinded, multi-center Phase IV study and randomized 1:1 to receive PEG + Asc (administered the evening before and the morning of colonoscopy, per label) or NaPic/MgCit (administered in the morning and afternoon the day before colonoscopy, per label). The blinded colonoscopist documented any lesion and assessed cleansing quality (Harefield Cleansing Scale). RESULTS Of 394 patients who completed the study, 393 (PEG + Asc, N = 200; NaPic/MgCit, N = 193) had a colonoscopy. Overall PDR for PEG+Asc versus NaPic/MgCit was 51.5% versus 44.0%, p = 0.139. PDR and ADR on the right side of the bowel were significantly higher with PEG + Asc versus NaPic/MgCit (PDR: 56[28.0%] versus 32[16.6%], p = 0.007; ADR: 42[21.0%] versus 23[11.9%], p = 0.015), as was detection of flat lesions (43[21.5%] versus 25[13.0%], p = 0.025). Cleansing quality was better with PEG + Asc than NaPic/MgCit (98.5% versus 57.5% considered successful cleansing). Overall, there were 132 treatment-emergent adverse events (93 versus 39 for PEG+Asc and NaPic/MgCit, respectively). These were mainly mild abdominal symptoms, all of which were reported for higher proportions of patients in the PEG+Asc than NaPic/MgCit group. Twice as many patients in the NaPic/MgCit versus the PEG + Asc group reported tolerance of cleansing solution as 'very good'. CONCLUSIONS Compared with NaPic/MgCit, PEG + Asc may be more efficacious for overall cleansing ability, and subsequent detection of right-sided and flat lesions. This is likely attributable to the different administration schedules of the two bowel cleansing preparations, which may positively impact the detection and prevention of colorectal cancer, thereby improving mortality rates. TRIAL REGISTRATION ClinicalTrials.gov NCT01689792.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the Efficacy, Adverse Effects, and Patient Compliance of the Sena-Graph Syrup and Castor Oil Regimens for Bowel Preparation

Sena-Graph syrup has recently been formulated by an Iranian pharmaceutical company for being used in bowel evacuation before radiography, colonoscopy and surgery. This study compares the efficacy, adverse effects and patient compliance of two bowel preparation regimens with castor oil and Sena-Graph syrup in of outpatients for Intravenous Urography (IVU). One hundred and fourteen consecutive ou...

متن کامل

A Comparison of the Efficacy, Adverse Effects, and Patient Compliance of the Sena-Graph Syrup and Castor Oil Regimens for Bowel Preparation

Sena-Graph syrup has recently been formulated by an Iranian pharmaceutical company for being used in bowel evacuation before radiography, colonoscopy and surgery. This study compares the efficacy, adverse effects and patient compliance of two bowel preparation regimens with castor oil and Sena-Graph syrup in of outpatients for Intravenous Urography (IVU). One hundred and fourteen consecutive ou...

متن کامل

High dose Senna or Poly Ethylene Glycol (PEG) for elective colonoscopy preparation: a prospective randomized investigator-blinded clinical trial

BACKGROUND The aim of this study was to determine the efficacy of two methods of colon preparation for colon cleansing in a randomized controlled trial. METHODS In this prospective randomized investigator-blinded trial, consecutive outpatients indicated for elective colonoscopy were randomized into two groups. Patients in Senna group took 24 tablets of 11 mg Senna in two divided doses 24 hour...

متن کامل

Effect of Polyethylene Glycol and Senna Bowel Preparation in Dogs on Some Hematological and Serum Biochemical Parameters

Background: Colonoscopy is the preferred procedure for diagnosis of large-bowel diseases in dogs. Polyethylene glycol (PEG) is the most commonly used laxative for colonic cleansing. Senna has been used in traditional medicine as a laxative and an aid to treat constipation. OBJECTIVES: The aim of this study was to evaluate the safety of senna as an alternative or adjunct to polyethylene glycol s...

متن کامل

Comparison of the Efficacy and Safety of Polyethylene Glycol and Senna Solutions in Colon Preparation before Colonoscopy in Dogs

Objective- The aim of this study was to evaluate the efficacy and safety of senna as an alternative or adjunct to polyethylene glycol (PEG) solution in dogs using colonoscopy and radiography.Design - Experimental study.Animals - 20 adult mongrel healthy dogs.Procedures- Dogs were randomly allocated to receive 1 of 4 different bowel preparation regimens including PEG, senna or ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015