BACKGROUND Precise evaluation of the aortic root geometry prior to transcatheter aortic valve implantation is important for procedural success in patients with aortic stenosis (AS). To determine the potential for 3-dimensional transesophageal echocardiography (3DTEE), the aims of the present study were: (1) to assess the accuracy of 3DTEE measurements of the aortic root using multidetector computed tomography (MDCT) as a reference, and (2) to examine whether aortic root geometry differs between patients with and without AS. METHODS AND RESULTS 3DTEE and contrast-enhanced MDCT were performed in 35 patients. Multiplanar reconstruction was used to measure the left ventricular outflow tract (LVOT) and aortic annulus diameter/area, aortic valve area (AVA), and distances between the annulus and coronary artery ostium. The same 3DTEE measurements were performed in patients with (n=71) and without AS (n=80). Aortic annular and LVOT areas measured by 3DTEE were slightly but significantly smaller compared with values obtained with MDCT. Both methods revealed that the aortic annulus and LVOT have an oval shape. Aortic annular and LVOT area, AVA and the distances between the aortic annulus and the coronary ostia correlated well between the 2 modalities. Only minor differences in aortic root geometry were observed between patients with AS and those without. CONCLUSIONS The geometry of the aortic annulus can be reliably evaluated using 3DTEE as an alternative to MDCT for the assessment of aortic root.
منابع مشابه
Quantitative Analysis of Aortic Valve Stenosis and Aortic Root Dimensions by Three-Dimensional Echocardiography in Patients Scheduled for Transcutaneous Aortic Valve Implantation
Accurate assessment of the aortic valve area (AVA) and evaluation of the aortic root are important for clinical decision-making in patients being considered for transcatheter aortic valve implantation (TAVI). Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) provides accurate and reliable quantitative assessment of aortic valve stenosis and the aortic root. We performed tw...
متن کاملLive/real time three-dimensional transesophageal echocardiographic evaluation of mitral and aortic valve prosthetic paravalvular regurgitation.
Thirteen patients already scheduled for surgery for repair of prosthetic paravalvular regurgitation underwent intraoperative real time two-dimensional transesophageal echocardiography (2D TEE) and live/real time three-dimensional transesophageal echocardiography (3D TEE). In all patients, 3D TEE was able to provide more information regarding the location and size of the paravalvular defect as c...
متن کاملA study of functional anatomy of aortic-mitral valve coupling using 3D matrix transesophageal echocardiography.
BACKGROUND Mitral and aortic valves are known to be coupled via fibrous tissue connecting the two annuli. Previous studies evaluating this coupling have been limited to experimental animals using invasive techniques. The new matrix array transesophageal transducer provides high-resolution real-time 3D images of both valves simultaneously. We sought to develop and test a technique for quantitati...
متن کاملTranscatheter intervention for complex ascending aortic pseudoaneurysm after cardiac surgery.
BACKGROUND Ascending aortic pseudoaneurysm (PsA) is an uncommon but surgically challenging problem with high morbidity and mortality. Herein we describe the efficacy and safety of the different approaches to transcatheter intervention for repair of ascending PsA and assess the selection of occluder devices using real-time 3-dimensional (RT 3D) color Doppler transesophageal echocardiography (TEE...
متن کاملA Framework for the Systematic Characterization of the Aortic Valve Complex by Real-Time Three Dimensional Echocardiography: Implications for Transcatheter Aortic Valve Replacement
Transcatheter aortic valve replacement (TAVR) has become a viable alternative to surgical aortic valve replacement in both high-risk and inoperable patients with symptomatic severe aortic stenosis [1]. A successful TAVR procedure is heavily dependent on appropriate patient selection and detailed morphologic characterization of the aortic valve complex to prevent device migration, coronary arter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 74 12 شماره
صفحات -