Tear lipids interfacial rheology: effect of lysozyme and lens care solutions.

نویسندگان

  • Tatyana F Svitova
  • Meng C Lin
چکیده

PURPOSE To evaluate the interfacial properties of ex vivo tear lipid multilayers with controlled and varying thickness. The influence of lysozyme and surfactant-containing multipurpose lens care solution (MPS) on interfacial rheology of lipids and mixed lipid-protein films were studied. METHODS Lipids were extracted from lotrafilcon A lenses worn continuously for 1 month. Interfacial properties of the lipids without and with lysozyme in the aqueous phase were examined using tensiometry and step-strain relaxation. Lipid-lysozyme multilayers were exposed to either diluted opti-free express (OFX) or opti-free replenish (OFR) for 30 min, and then MPS was displaced from the bulk phase. Surface tension and rheological parameters before and after MPS exposure were measured and compared. RESULTS Thick lipid films exerted high surface pressure at the air-aqueous interface, 50 +/- 2 mN/m, with little inter- and intrasubject variability. The rheological storage modulus (E(infinity); 25.3 +/- 2 mN/m) and relaxation time (tau; 87 +/- 25 s) were similar among subjects. Neither lysozyme nor MPS changed the surface tension of the lipid multilayers. Lysozyme adsorbed irreversibly onto multilayers without changing E(infinity), but increased tau 2.5 times. Exposure of mixed multilayers to OFX reduced E(infinity) to less than a half of its original value (13 +/- 4.5 mN/m; p < 0.001), whereas after OFR exposure, small but statistically significant changes in E(infinity) were found (21 +/- 3.0 mN/m; p = 0.0044). MPS-treated mixed films relaxed much slower than an untreated one, tau increased 4.5 times after OFX and 7 times after OFR exposure. CONCLUSIONS Thick multilayers of the ex vivo tear lipids have exhibited surface tension 15 +/- 1 mN/m lower than reported in the literature for meibomian lipids. The lipid-lysozyme interaction altered the interfacial rheology of the ex vivo lipids. OFX and OFR changed rheological properties of the mixed films to different extents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses

Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel ...

متن کامل

Detection and quantification of tear phospholipids and cholesterol in contact lens deposits: the effect of contact lens material and lens care solution.

PURPOSE To examine the deposition of tear phospholipids and cholesterol onto worn contact lenses and the effect of lens material and lens care solution. METHODS Lipids were extracted from tears and worn contact lenses using 2:1 chloroform:methanol and the extract washed with aqueous ammonium acetate, before analysis by electrospray ionization tandem mass spectrometry (ESI-MS/MS). RESULTS Tw...

متن کامل

Corneal Cell Adhesion to Contact Lens Hydrogel Materials Enhanced via Tear Film Protein Deposition

Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the...

متن کامل

In-vitro analysis of the microbicidal activity of 6 contact lens care solutions

BACKGROUND Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been ...

متن کامل

Structural and rheological properties of meibomian lipid.

PURPOSE We explore the unique rheological and structural properties of human and bovine meibomian lipids to provide insight into the physical behavior of the human tear-film lipid layer (TFLL). METHODS Bulk rheological properties of pooled meibomian lipids were measured by a commercial stress-controlled rheometer; a home-built interfacial stress rheometer (ISR) probed the interfacial viscoela...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 87 1  شماره 

صفحات  -

تاریخ انتشار 2010