Comparison of high‐dose‐rate intracavitary brachytherapy dosimetry with and without anesthesia in patients with cervical carcinoma

نویسندگان

  • Daya N. Sharma
  • Pritee Chaudhari
  • Seema Sharma
  • Leena Gupta
  • Pandjatcharam Jagadesan
  • Goura K. Rath
  • Pramod K. Julka
چکیده

This study compares the dosimetry of high-dose-rate intracavitary brachytherapy (HDR-ICBT) performed with and without general anesthesia/spinal anesthesia (GA/SA) in patients with cervical carcinoma. We retrospectively retrieved the records of 138 HDR-ICBT applicator insertions performed in 46 patients: 69 performed with GA/SA (anesthesia group known as AG) in 23 patients, and 69 performed without GA/SA (nonanesthesia group known as NAG) in 23 patients. The intracavitary brachytherapy (ICBT) application was done with central tandem and two vaginal ovoids. For each ICBT plan, a high-dose-rate (HDR) dose of 7 Gy was prescribed to point A. From each plan, the doses to Point B right (B(R)), Point B left (B(L)), bladder and rectal reference points (Bladder(ref) and Rectal(ref)) were recorded and compared in the two groups. Student's t-test was applied to find out the significance of difference. The two groups were comparable in terms of demography and clinical characteristics. Mean Point BL doses in AG and NAG were 1.89 Gy (27% of Point A dose) and 1.82 Gy (26% of Point A dose), respectively. Mean Point BR doses in AG and NAG were 1.91 Gy (27% of Point A dose) and 1.85 Gy (26% of point A), respectively (p-value 0.7). The mean dose to Bladder(ref) in AG and NAG was 5.03 Gy and 4.90 Gy, respectively (p-value 0.6). The mean dose to Rectal(ref) was significantly higher in AG than NAG (5.09 Gy vs. 4.49 Gy, p-value 0.01). Although based on conventional 2D dosimetry planning, our study has demonstrated that avoiding GA/SA does not result in inferior HDR-ICBT dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

متن کامل

Caudal epidural anesthesia during intracavitary brachytherapy for cervical cancer

It has been suggested that pain control during intracavitary brachytherapy for cervical cancer is insufficient in most hospitals in Japan. Our hospital began using caudal epidural anesthesia during high-dose-rate (HDR) intracavitary brachytherapy in 2011. The purpose of the present study was to retrospectively investigate the effects of caudal epidural anesthesia during HDR intracavitary brachy...

متن کامل

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

متن کامل

درمان داخل حفره‌ای در مبتلایان سرطان سرویکس: پرتودهی با دوز متوسط در یک مطالعه آینده‌نگر

Background: Treatment of cervical carcinoma is routinely performed with Low Dose Rate (LDR) brachytherapy, but Brachytherapy in our department is done with Medium Dose Rate (MDR) due to the technical characteristics of the machine available here. Thus we decided to evaluate the results of this treatment in our department in a prospective study. Methods: Between March 2006 and July 2008, 140 pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014