High-pressure liquid chromatographic quantitation of azlocillin.

نویسندگان

  • A Weber
  • K E Opheim
  • K Wong
  • A L Smith
چکیده

We describe a rapid, precise, and simple procedure for the quantitation of azlocillin in serum and in aqueous solutions by high-pressure, reverse-phase liquid chromatography. This method uses a single precipitation step, detection by dual-wavelength monitoring (220 and 254 nm), and quantitation by comparison with an internal standard. The 10-micron C18 muBondapak column was eluted with 45% (vol/vol) methanol-65% (vol/vol) phosphate buffer. The precision was 4.2 and 5.6% at 50 and 10 micrograms/ml, respectively. The assay was linear up to concentrations of 100 micrograms/ml, with recoveries of 90.4 to 110.5% from serum. The assay was sensitive to 0.4 micrograms of azlocillin per ml. The short turnover time (14 min) and small serum sample size (20 microliters) make the assay ideal for therapeutic drug monitoring and clinical pharmacokinetic studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of use of a specific monoclonal antibody on radioimmunoassay results for serum cyclosporine.

2156 CLINICALCHEMISTRY, Vol. 34, No. 10, 1988 3. Gundert-Remy N, DeVries JX. Determination of ureidopemcillins azlocillin, mezlocillin, and Bay K 4999 in plasma by high performance liquid chromatography. Br J Clin Pharmacol 1979;8:589-92. 4. Fasching CE, Peterson LR. High-pressure liquid chromatographic assay of azlocillinand meziocillinwith an anion-exchange extractiontechnique.J Liq Chromatog...

متن کامل

Effect of Use of a Specific Monoclonal Antibody on Radloimmunoassay Results for Serum Cyclosporlne,

2156 CLINICALCHEMISTRY, Vol. 34, No. 10, 1988 3. Gundert-Remy N, DeVries JX. Determination of ureidopemcillins azlocillin, mezlocillin, and Bay K 4999 in plasma by high performance liquid chromatography. Br J Clin Pharmacol 1979;8:589-92. 4. Fasching CE, Peterson LR. High-pressure liquid chromatographic assay of azlocillinand meziocillinwith an anion-exchange extractiontechnique.J Liq Chromatog...

متن کامل

Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma

Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...

متن کامل

High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma

The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...

متن کامل

High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma

The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 1983