A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial.

نویسندگان

  • P Triclot
  • G Grosjean
  • F El Masri
  • J P Courpied
  • M Hamadouche
چکیده

We carried out a prospective randomised study designed to compare the penetration rate of acetabular polyethylene inserts of identical design but different levels of cross-linking at a minimum of four years follow-up. A total of 102 patients (102 hips) were randomised to receive either highly cross-linked Durasul, or contemporary Sulene polyethylene inserts at total hip replacement. A single blinded observer used the Martell system to assess penetration of the femoral head. At a mean follow-up of 4.9 years (4.2 to 6.1) the mean femoral head penetration rate was 0.025 mm/year (SD 0.128) in the Durasul group compared with 0.106 mm/year (SD 0.109) in the Sulene group (Mann-Whitney test, p = 0.0027). The mean volumetric penetration rate was 29.24 mm(3)/year (SD 44.08) in the Durasul group compared with 53.32 mm(3)/year (SD 48.68) in the Sulene group. The yearly volumetric penetration rate was 55% lower in the Durasul group (Mann-Whitney test, p = 0.0058). Longer term results are needed to investigate whether less osteolysis will occur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis.

The creep and wear behaviour of highly cross-linked polyethylene and standard polyethylene liners were examined in a prospective, double-blind randomised, controlled trial using radiostereometric analysis. We randomised 54 patients to receive hip replacements with either highly cross-linked polyethylene or standard liners and determined the three-dimensional penetration of the liners over three...

متن کامل

Wear of a sequentially annealed polyethylene acetabular liner

BACKGROUND AND PURPOSE We previously reported on a randomized controlled trial (RCT) that examined the effect of adding tobramycin to bone cement after femoral stem migration. The present study examined femoral head penetration into both conventional and highly crosslinked polyethylene acetabular liners in the same group of RCT patients, with a minimum of 5 years of postoperative follow-up. P...

متن کامل

Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

BACKGROUND Radiostereometric analysis provides highly precise measurements of component micromotion relative to the bone that is otherwise undetectable by routine radiographs. This study compared, at a minimum of five years following surgery, the micromotion of tantalum and titanium acetabular cups and femoral head penetration in highly cross-linked polyethylene liners and conventional (ultra-h...

متن کامل

Highly cross-linked polyethylene acetabular liners retrieved four to five years after revision surgery: a report of two cases.

There is currently considerable interest in the use of highly cross-linked polyethylene (XLPE) acetabular liners for total hip arthroplasty (THA). In literature, only a single retrieval analysis of one type of XLPE liner implanted for greater than four years exists. The purpose of the present report is to quantify surface deviations in two XLPE liners implanted during revision THA and retrieved...

متن کامل

Correlation Between In Vivo Oxidation and Mechanical Properties In Contemporary Polyethylene Bearings

Introduction: Ultra-high molecular weight polyethylene oxidation remains an important concern in total joint arthroplasty, since it eventually results in a significant drop in mechanical properties that may compromise implant longevity, especially for TKA [1-3]. In vivo oxidation of polyethylene can occur in the presence of unstabilized macroradicals within the polymer and molecular oxygen upta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 89 11  شماره 

صفحات  -

تاریخ انتشار 2007