CyberKnife radiotherapy for localized prostate cancer: rationale and technical feasibility.

نویسندگان

  • Christopher R King
  • Joerg Lehmann
  • John R Adler
  • Jenny Hai
چکیده

There is a clear dose response for localized prostate cancer radiotherapy and there probably is a radiobiological rationale for hypo-fractionation. Combining the two should maximize tumor control and increase the therapeutic ratio. This study examines the rationale and technical feasibility of CyberKnife radiotherapy (a robotic arm-driven linear accelerator) for localized prostate cancer. Its ability to deliver non-coplanar non-isocentric arcs can yield maximally conformal isodoses. It is the only integrated system capable of target position verification and real-time tracking during delivery of conformal stereotactic radiotherapy. Inverse planning with the CyberKnife is used to design a course of radiotherapy for localized prostate cancer. Fiducial markers within the gland are used to verify organ position and track organ motion via an orthogonal pair of electronic x-ray imaging devices and provide real-time feedback correction to the robotic arm during delivery. Conformal isodose curves and dose volume histograms (DVH) are used to compare with an optimized Intensity-Modulated Radiotherapy (IMRT) plan actually delivered to the study patient based upon CT scan-derived organ volumes. The CyberKnife can produce superior DVHs for sparing of rectum and bladder and excellent DVHs for target coverage compared with IMRT, and possesses dose heterogeneities to the same degree as IMRT plans. Because of the significantly longer delivery times required it would be best suited for hypo-fractionated regimens. Such dose regimens might allow for biologically equivalent dose escalation without increased normal tissue toxicity. Since the CyberKnife can verify organ position and motion and correct for this in real-time it is the ideal means of achieving such excellent DVHs without a compromise in doses to normal tissues. These capabilities are essential if one contemplates hypo-fractionated regimens with large dose-per-fraction sizes (>5Gy to 10Gy) and dose-escalation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prostate-specific antigen kinetics after hypofractionated stereotactic body radiotherapy for localized prostate cancer

Background: stereotactic body radiotherapy (SBRT) has emerged as an effective treatment for localized prostate cancer. However, prostate-specific antigen (PSA) kinetics after SBRT has not been well characterized. The objective of the current study is to analyze the rate of PSA decline and PSA nadir following hypofractonated SBRT in localized prostate cancer. Materials and Methods: From 2008...

متن کامل

Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer

Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

CyberKnife in the treatment of prostate cancer: a revolutionary system.

The CyberKnife is a frameless advanced robotic system that uses image-guided radiotherapy (IGRT) and adaptive radiotherapy (ART) for stereotactic radiosurgery technique in intraand extracranial lesions. The CyberKnife has also revolutionised the use of radiosurgery to treat tumours in different parts of the body. This system represents, after three-dimensional conformal radiotherapy (3DCRT), a ...

متن کامل

Stereotactic body radiotherapy for low-risk prostate cancer: five-year outcomes

PURPOSE Hypofractionated, stereotactic body radiotherapy (SBRT) is an emerging treatment approach for prostate cancer. We present the outcomes for low-risk prostate cancer patients with a median follow-up of 5 years after SBRT. METHOD AND MATERIALS Between Dec. 2003 and Dec. 2005, a pooled cohort of 41 consecutive patients from Stanford, CA and Naples, FL received SBRT with CyberKnife for cli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Technology in cancer research & treatment

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2003