Mechanical testing of absorbable suture anchors.
نویسندگان
چکیده
PURPOSE Absorbable suture anchors offer great advantages but are made of mechanically weak material. The weakest link in the fixation of soft tissue to bone may therefore be the anchor itself. In this study, several commercially available anchors were mechanically tested in vitro. TYPE OF STUDY Biomechanical bench study. METHODS Twelve absorbable suture anchor models were implanted into an artificial test bone according to the recommended technique. Testing temperature was 37 degrees C +/- 1 degrees C. The anchors were loaded with an Instron testing machine with the suture material (USP No. 2, Ethibond, Ethicon, Somerville, NJ) in line with the anchor axis, with and without previous abrasion of the suture at the eyelet. Tensile load at failure and failure mode were recorded. To test creep behavior, a permanent load of 100 N was applied to the anchors, and time to failure was recorded. Suture anchor weight and crystallinity were analyzed. RESULTS Mean failure load on tensile testing using a cross-head speed of 60 mm/min ranged from 124 to 244 N. Failure modes were eyelet failure in 5 cases, suture failure in 6 cases, and anchor pullout in 1 case. In creep testing, eyelet failure occurred in 8 anchor models after a mean duration of 0.5 to 99 hours; 3 anchor models remained intact after 300 hours, and 1 anchor model failed by pullout of the test sample. Crystallinity ranged from 0% (amorphous) to 57.2%; anchor weight ranged from 0.036 to 0.161 g. Mechanical properties did not correlate with crystallinity but with anchor weight. Abrasion of the suture material at the eyelet had little effect on failure load. CONCLUSIONS At 37 degrees C, structural failure (breaking) of absorbable suture anchors may occur if loaded to the mechanical limit. Absorbable anchors are particularly sensitive to static, long-term loading.
منابع مشابه
Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor.
Bioabsorbable suture anchors are commonly used for arthroscopic repair of rotator cuff and labrum lesions. They provide soft-tissue attachment to bone. They have been introduced to avoid complications such as artefacts on MRI scans, commonly seen with metal anchors. However, bioabsorbable implants may lead to other problems such as local osteolysis, cyst formation, soft tissue inflammation and ...
متن کاملSuture locking of isolated internal locking knotless suture anchors is not affected by bone quality
PURPOSE The purpose of this study was to evaluate the mechanical performance of different suture locking mechanisms including: i) interference fit between the anchor and the bone (eg, 4.5 mm PushLock, 5.5 mm SwiveLock), ii) internal locking mechanism within the anchor itself (eg, 5.5 mm SpeedScrew), or iii) a combination of interference fit and internal locking (eg, 4.5 mm MultiFIX P, 5.5 mm Mu...
متن کاملMechanical strength of repairs of the rotator cuff.
We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We the...
متن کاملMechanical properties of all-suture anchors for rotator cuff repair
OBJECTIVES All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. MATERIALS AND METHODS A total of four commercially available all-suture anchors, the 'Y-Knot' (ConMed), Q-FIX (Smith ...
متن کاملLong term results of arthroscopic bankart repair for traumatic anterior shoulder instability
BACKGROUND The arthroscopic method offers a less invasive technique of Bankart repair for traumatic anterior shoulder instability. We would like to report the 2 year clinical outcomes of bio-absorbable suture anchors used in traumatic anterior dislocations of the shoulder. METHODS Data from 79 shoulders in 74 patients were collected over 4 years (2004-2008). Each patient was followed-up over ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2003