Intracuff pressures of endotracheal tubes in the management of airway emergencies: the need for pressure monitoring.

نویسندگان

  • Michel Galinski
  • Virginie Tréoux
  • Bruno Garrigue
  • Frédéric Lapostolle
  • Stephen W Borron
  • Frédéric Adnet
چکیده

STUDY OBJECTIVE Excessive pressure exerted on the tracheal mucosa is an avoidable factor implicated as a cause of damage after intubation of the trachea with cuffed tubes. Many patients are intubated in the out-of-hospital setting by emergency medical teams. The time spent in the out-of-hospital setting could very well be long enough for tracheal mucosal damage to occur if cuff pressure is not controlled. The objective of this study is to assess the incidence of intracuff excessive pressure in the out-of-hospital setting. METHODS We performed an observational prospective study. Every patient who required tracheal intubation was included in the study, regardless of indication. When the patient was stabilized, the cuff was connected to a manometer, and pressure was systematically recorded. Corrections to inflation were performed if necessary to achieve a cuff pressure of 14 to 27 cm H2O. RESULTS One hundred seven patients were included. Eighty-five were out-of-hospital patients and 22 were transfers between 2 hospitals who had been previously intubated when the mobile intensive care unit team arrived. The first recorded cuff pressures were greater than 27 cm H2O among 79% of patients (85/107), with a mean pressure of 56 cm H2O (SD+/-34 cm H2O) in out-of-hospital patients and 69 cm H2O (SD+/-37 cm H2O) for transferred patients. Pressure correction was made in 72% of patients (77/107). There were corrections in 69% (59/85) of out-of-hospital patients and 82% (18/22) of transferred patients. CONCLUSION This study revealed that the majority of cuff pressures exceeded safe pressure and required correction. Frequent measurement and adjustment of cuff pressure has been recommended, but this method requires a specific manometer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review

Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...

متن کامل

A comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement.

Cuffed endotracheal tubes are one aspect of airway management designed to ensure safety, yet patients can be at risk for injury from underinflated and overinflated endotracheal cuffs. Tracheal pressures exceeding approximately 48 cm H2O impede capillary blood flow, potentially causing tracheal damage, and pressures below approximately 18 mm Hg may increase the risk of aspiration. There is no st...

متن کامل

Leakage of fluid around endotracheal tube cuffs: a cadaver study

BACKGROUND The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. METHODS Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülk...

متن کامل

Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics.

This study compared intracuff pressure (ICP) during mechanical ventilation in a variety of currently used endotracheal (ET) and tracheostomy (trach) tube cuffs and related cuff physical characteristics. Tracheostomy tube physical characteristics were also measured. Variation was observed to exist between "just-seal" inspiratory and end-expiratory intracuff pressure during mechanical ventilation...

متن کامل

Pediatric cuffed endotracheal tubes: an evolution of care.

PURPOSE To examine the history of pediatric endotracheal intubation and the issues surrounding the change from uncuffed endotracheal tubes to cuffed endotracheal tubes, including pediatric airway anatomy, endotracheal tube design, complications, and safety concerns. METHOD Review of the literature. CONCLUSIONS Although the use of cuffed endotracheal tubes in infants and children remains a t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of emergency medicine

دوره 47 6  شماره 

صفحات  -

تاریخ انتشار 2006