A polymer film modified sensor for voltammetric determination of uric acid in the presence of ascorbic Acid and its application in urine.

نویسندگان

  • Ailin Liu
  • Wei Chen
  • Liying Huang
  • Xinhua Lin
چکیده

A novel uric acid electrochemical sensor was fabricated by electropolymerization on glassy carbon electrode (GCE) with 4-(2-pyridylazo)-resorcinol (PAR) and its electrochemical property was investigated through cyclic voltammetry. The effect of film thickness on the oxidation response was also studied by electropolymerized scan times. The voltammetric behavior of uric acid (UA) was studied with the poly PAR modified GCE. The modified GCE was used to electrochemically detect the individual of UA and the mixture of UA and ascorbic acid (AA) by cyclic voltammetry (CV) or differential pulse voltammetry (DPV) method. For the ternary mixture containing UA and AA, the two compounds can well be separated from each other at a scan rate of 100 mV s(-1) with a potential difference of 345 mV in DPV between UA and AA. The peak currents of UA oxidation increase linearly with the concentration in ranges of 1.0x10(-8)-5.0x10(-5) mol l(-1), and the detection limits (S/N=3) was 1.0x10(-9) mol l(-1). This method was successfully applied to the determination of uric acid in human urine samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube

In this study, incorporation of iron ion-doped natrolite nanozeolite, multi-wall carbon nanotubes into chitosan-coated glassy carbon electrode for the simultaneous determination of ascorbic acid, epinephrine, uric acid and tyrosine is studied. The results show that the combination of multi-wall carbon nanotubes and iron ion-doped natrolite zeolite causes a dramatic enhancement in the sensitivit...

متن کامل

Sensitive Voltammetric Determination of Acetaminophen at Poly(4-vinyl pyridine)/Graphene Composite Modified Electrode

This study demonstrates the use of a selective and sensitive voltammetric sensor for determination of acetaminophen (AC). This was  performed by modifying a glassy carbon electrode with composite film of poly(4-vinylpyridine) and graphene sheet (P4VP/GR-GCE). The redox peak currents of AC increased significantly at P4VP/GR-GCE. The result was achieved by the synergistic effect of combined elect...

متن کامل

Fabrication of TiO2 Hollow Spheres and its Application in Modification of Carbon Paste Electrode For Simultaneous Determination of Dopamine and Piroxicam in the Presence of Ascorbic acid

In this work we report preparation TiO2 hollow spheres and its application as an electrochemical sensor. Therefore the novel carbon paste electrode modified with TiO2 hollow spheres (TOHS), multi-walled carbon nanotubes (MWCNTs) and poly-glutamic acid (PGA) film (PGA/TOHS/MWCNTs/CPE) was used for simultaneous determination of dopamine (DA) and piroxicam (PRX) in the presence of ascorbic acid (A...

متن کامل

Simultaneous determination of dopamine and uric acid using a glassy carbon paste electrode modified with copper- para red complex

A simple approach based on cyclic voltammetry (CV) was developed for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) using a modified glassy carbon paste electrode (GCPE). In the present study, analytical parameters were optimized and electrochemical performance of modified electrode was investigated. The calibration curves were obtained ...

متن کامل

Fabrication of Nano Poly Cresol Red over Glassy Carbon Electrode and its Application in Selective Determination of Uric acid in the Presence of Ascorbic Acid

A selective electrochemical method for the determination of uric acid was developed by using nano poly cresol red modified glassy carbon electrode. This new material has been characterized by Scanning Electron Microscopy, cyclic voltammetry and Differential pulse voltammetry. This modified electrode shows excellent electrocatalytic activity towards the oxidation of uric acid in the presence of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical & pharmaceutical bulletin

دوره 56 12  شماره 

صفحات  -

تاریخ انتشار 2008