Cryogenic ion trapping systems with surface-electrode traps.

نویسندگان

  • P B Antohi
  • D Schuster
  • G M Akselrod
  • J Labaziewicz
  • Y Ge
  • Z Lin
  • W S Bakr
  • I L Chuang
چکیده

We present two simple cryogenic rf ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 h. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The vibration amplitude of the closed cycled cryostat was found to be below 106 nm. We evaluated the systems by loading surface-electrode ion traps with (88)Sr(+) ions using laser ablation, which is compatible with the cryogenic environment. Using Doppler cooling we observed small ion crystals in which optically resolved ions have a trapped lifetime over 2500 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

8 Cryogenic ion trapping systems with surface - electrode traps

P. B. Antohi, D. Schuster, G. M. Akselrod, J. Labaziewicz, Y. Ge, Z. Lin, W. S. Bakr, and I. L. Chuang Center for Ultracold Atoms, Department of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA Department of Applied Physics, Yale University, New Haven, CT 06511, USA Center for Ultracold Atoms, Department of Physics, Harvard University, Cambridge, MA 02138, USA (Dated: Fe...

متن کامل

Suppression of heating rates in cryogenic surface-electrode ion traps.

Dense arrays of trapped ions provide one way of scaling up ion trap quantum information processing. However, miniaturization of ion traps is currently limited by sharply increasing motional state decoherence at sub-100 mum ion-electrode distances. We characterize heating rates in cryogenically cooled surface-electrode traps, with characteristic sizes in the 75 to 150 mum range. Upon cooling to ...

متن کامل

Radiofrequency multipole traps: Tools for spectroscopy and dynamics of cold molecular ions

Multipole radiofrequency ion traps are a highly versatile tool to study molecular ions and their interactions in a well-controllable environment. In particular the cryogenic 22-pole ion trap configuration is used to study ion-molecule reactions and complex molecular spectroscopy at temperatures between few Kelvin and room temperatures. This article presents a tutorial on radiofrequency ion trap...

متن کامل

Comparative numerical studies of ion traps with integrated optical cavities

We study a range of radio-frequency ion trap geometries and investigate the effect of integrating dielectric cavity mirrors on their trapping potential using numerical modelling. We compare five different ion trap geometries with the aim to identify ion trap and cavity configurations that are best suited for achieving small cavity volumes and thus large ion-photon coupling as required for scala...

متن کامل

Planar Electrode Quadrupole Ion Traps

We present a linear type ion trap consisting of metal lines that are lithographically patterned onto two ceramic substrates. Trapping fields are realized by applying specific voltage potentials to each line. This arrangement allows miniaturization approaches that are immune to surface roughness issues and increased complexities of precision machining of electrode surfaces. We also present how t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 2009