The value of high fidelity electrocardiography using the cathode ray oscillograph and an expanded time scale.

نویسنده

  • P H LANGNER
چکیده

The cathode ray is practically free from inertia and therefore an ideal instrumentality for studying variations in electrical potential. A cathode ray oscilloscope with an amplifier system of high frequency response and an expanded time scale, 330 mm. per second, were employed to record electrocardiograms. Such tracings revealed considerable notching, slurring, and other peculiarities not seen in the conventional electrocardiographic records on the same individuals. An instrument should have a frequency response curve flat to well over 330 cycles per second to record faithfully the human electrocardiogram. This is much higher than the frequency response of instruments usually used for electrocardiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An electronic phonocardiograph employing a double-beam cathode-ray oscillograph as the recording device.

A phonocardiograph employing a cathode-ray tube is the theoretical ideal since the natural frequency of the instrument is sufficiently high to avoid distortion of the vibrations to be recorded, the amplitude of the deflections is directly proportional to the movements which excite them, and the cathode-ray beam has minimal inertia and is fully damped. With any of the popular recording devices i...

متن کامل

The effect of the frequency response of electrocardiographs on the form of electrocardiograms and vectorcardiograms.

The spectrum of frequencies making up the cardiac potential has not been fully explored. Limitation in the high frequency response of most electrocardiographs suppresses in some tracings QRS components whose significance is at present obscure. Using the cathode ray oscillograph it was found that frequencies as high as 1300 cycles per second reveal characteristics not shown at lower frequencies....

متن کامل

A high performance lithium-ion battery using LiNa0.02K0.01FePO4/C as cathode material and anatase TiO2 nanotube arrays as anode material

In this paper we report on a lithium ion battery (LIB) based on improved olivine lithium iron phosphate/carbon (LiFePO4/C) as cathode material and LiNa0.02K0.01FePO4/C  synthesized by sol-gel method and TiO2 nanotube arrays (TNAs) with an anatase phasesynthesized through anodization of Ti foil as an anode electrode. Crystallographic structure and surface morphology of the cathode and anode mate...

متن کامل

Synthesis and Characterization of LiMnPO4/Carbon Nanocomposite Material as Cathode Material

Development of an eco-friendly, low cost and high energy density LiMnPO4 cathode material has attracted much attention due to its high operating voltage vs. Li falling within the electrochemical stability window of conventional electrolyte solutions and offers more safety features due to the presence of a strong P-O covalent bond.Synthesis of battery materials integrates the...

متن کامل

Design and Simulation of Hot Cathode Ionization Vacuum Gauge with no X-Ray Limitations

In this paper, the MEMS type ionization gauge with no X-Ray limitations has been presented. Having the dimensions of 2.4 mm× 0.8mm × 1.4 mm, the designed gauge is 9000 times smaller than the conventional type and can operate in HV and UHV pressures up to 5×10-9 torr. Operating at the temperature of 750°C, the cathode of proposed gauge is implemented using nickel and works in a way in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 1952