Temperature inaccuracies during cardiopulmonary bypass.
نویسندگان
چکیده
Cerebral hyperthermia caused by perfusate temperature greater than 37 degrees C during the rewarming phase of CPB has been linked to postoperative neurologic deficits. The purpose of this study was to determine the accuracy of the coupled temperature measurement system and the CDI 500 arterial temperature sensor. Seventeen patients undergoing CPB were divided into four groups, each with a different temperature probe coupled to the oxygenator. The coupled temperature measurement system and CDI temperature sensors were compared with an indwelling probe placed in direct contact with the arterial perfusate. Blood, bladder, room and water temperatures, arterial line pressure, blood flow, and hemoglobin were recorded while the patients were supported with CPB. The actual blood temperature was significantly higher than the coupled temperature measurement system for two of the four groups (mean = 1.61 degrees C and 0.91 degrees C, p < 0.0001). A significant positive correlation between the actual temperature and the coupled temperature measurement system error was observed for the same two groups (r = 0.44, p < 0.0001). The actual temperature was significantly higher than the CDI temperature in all patients (mean = 1.2 degrees C, p < 0.0001). The coupling mechanism on the oxygenator generates inconsistent temperature readings. The perfusionist should consider these inconsistencies when using coupled temperature measurements and may consider the use of a direct temperature measurement system. The CDI temperature error is probably the result of inadequate flow through the sensor. On the test circuit, the flow of 170 mL/min was inadequate for circuit temperature accuracy. The accuracy of the CDI temperature drastically improved when the flow-through the sensor was increased to approximately 400 mL/min. Thus, the perfusionist must ensure adequate flow through the sensor in order for the temperature mechanism to function properly. Finally, the perfusionist can prevent cerebral hyperthermia by not allowing water temperature to exceed 37 degrees C, when using a coupled temperature measurement system.
منابع مشابه
Effect of temperature and cardiopulmonary bypass on the pharmacokinetics of remifentanil.
Sixteen patients undergoing coronary revascularization requiring cardiopulmonary bypass received remifentanil 2 micrograms kg-1 or 5 micrograms kg-1 by infusion over 1 min after sternotomy but before commencing cardiopulmonary bypass, during hypothermic cardiopulmonary bypass and during cardiopulmonary bypass after rewarming. Hypothermic cardiopulmonary bypass reduced the clearance of remifenta...
متن کاملProblems of Cold Agglutinins in Cardiac Surgery: How to Manage Cardiopulmonary Bypass and Myocardial Protection
Cold agglutinins are of unique relevance in cardiac surgerybecause of the use of hypothermic cardiopulmonary bypass (CPB). Cold autoimmune diseases are defined by the presence of abnormal circulating proteins (usually IgM or IgA antibodies) that agglutinate in response to a decrease in body temperature. These disorders include cryoglobulinemia and cold hemagglutinin disease.Immunoglobulin M aut...
متن کاملDuring Hypothermic Cardiopulmonary Bypass-Correlation with Oxyhemoglobin Saturation
In 8 adult patients undergoing cardiopulmonary bypass, the perfusion flow was altered from 2.4 to 1.8 and 1.2 L/min/m during hypothermia (26.5 ± 2.3°C). Following rewarming of the patients to 37°C, the perfusion flow was also altered from 2.4 to 1.8 and 1.2 L/min/m • The resulting mixed venous oxyhemoglobin saturation (Sv0 2 ) was measured in vivo by in-line oximetry at the actual body temperat...
متن کاملCerebral oxygenation during cardiopulmonary bypass in children.
OBJECTIVE Previous work has found cerebral oxygen extraction to decrease during hypothermic cardiopulmonary bypass in children. To elucidate cardiopulmonary bypass factors controlling cerebral oxygen extraction, we examined the effect of perfusate temperature, pump flow rate, and hematocrit value on cerebral hemoglobin-oxygen saturation as measured by near infrared spectroscopy. METHODS Forty...
متن کاملCerebral Artery During Nonpulsatile Hypothermic Cardiopulmonary Bypass
Background and Purpose We evaluated the utility of blood flow velocity measurements by transcranial Doppler ultrasonography as a tool to indirectly measure cerebral perfusion during cardiopulmonary bypass. Methods We simultaneously measured blood flow velocity in the middle cerebral artery and physiological variables in 18 patients undergoing cardiac surgery under hypothermic cardiopulmonary by...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 37 1 شماره
صفحات -
تاریخ انتشار 2005