In vitro validation of the luminal measurement of a novel catheter based moulding technique.
نویسندگان
چکیده
OBJECTIVE To investigate a modified angioplasty balloon catheter, which uses a novel balloon polymer to produce luminal moulds. DESIGN The catheter was tested in polyurethane phantoms of diameter 1.5 to 4.0 mm. Inflations were to 1.4 atmospheres for 20 seconds at 37 degrees C. The moulds were viewed by reinflating the balloon to 0. 34 atmospheres and quantified using macrophotography and caliper measurement. RESULTS Evidence of systematic error was found with lumen diameters </= 2.0 mm, accuracy being 0.32 to 0.80 mm and precision 0.23 to 0.24 mm. However, between 2.5 and 4.0 mm the accuracy of measuring luminal diameters was 0.01 mm, the precision 0. 06 mm, and the absolute mean error 0.05 mm. The results for percentage diameter stenosis were -1.15%, 0.86%, and 1.21%, and for lesion length they were 0.20, 0.60, and 0.41 mm, respectively. CONCLUSIONS The prototype catheter shows a high degree of accuracy and precision in phantoms of diameter 2.5 to 4.0 mm-the range within which most interventional work is performed. Further work on this technique as a method of direct three dimensional moulding of the coronary artery lumen is warranted.
منابع مشابه
The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملA NOVEL FUZZY-BASED SIMILARITY MEASURE FOR COLLABORATIVE FILTERING TO ALLEVIATE THE SPARSITY PROBLEM
Memory-based collaborative filtering is the most popular approach to build recommender systems. Despite its success in many applications, it still suffers from several major limitations, including data sparsity. Sparse data affect the quality of the user similarity measurement and consequently the quality of the recommender system. In this paper, we propose a novel user similarity measure based...
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملAttitudes towards English as an International Language (EIL) in Iran: Development and Validation of a New Model and Questionnaire
This study aimed at developing and validating a new model and instrument to explore attitudes of Iranian EFL learners towards English as an International Language (EIL). In so doing, the researchers followed several rigorous steps including extensive literature review, content selection, item generation, designing the rating scales and personal information part, Delphi technique, item revision,...
متن کاملNeuro-Fuzzy Based Algorithm for Online Dynamic Voltage Stability Status Prediction Using Wide-Area Phasor Measurements
In this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. This technique uses synchronized phasors measured by phasor measurement units (PMUs) in a wide-area measurement system. In order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Heart
دوره 81 2 شماره
صفحات -
تاریخ انتشار 1999