Equipment review: Mechanical effects of heat-moisture exchangers in ventilated patients

نویسندگان

  • Giorgio A Iotti
  • Maddalena C Olivei
  • Antonio Braschi
چکیده

Although they represent a valuable alternative to heated humidifiers, artificial noses have unfavourable mechanical effects. Most important of these is the increase in dead space, with consequent increase in the ventilation requirement. Also, artificial noses increase the inspiratory and expiratory resistance of the apparatus, and may mildly increase intrinsic positive end-expiratory pressure. The significance of these effects depends on the design and function of the artificial nose. The pure humidifying function results in just a moderate increase in dead space and resistance of the apparatus, whereas the combination of a filtering function with the humidifying function may critically increase the volume and the resistance of the artificial nose, especially when a mechanical filter is used. The increase in the inspiratory load of ventilation that is imposed by artificial noses, which is particularly significant for the combined heat-moisture exchanger filters, should be compensated for by an increase either in ventilator output or in patient's work of breathing. Although both approaches can be tolerated by most patients, some exceptions should be considered. The increased pressure and volume that are required to compensate for the artificial nose application increase the risk of barotrauma and volutrauma in those patients who have the most severe alterations in respiratory mechanics. Moreover, those patients who have very limited respiratory reserve may not be able to compensate for the inspiratory work imposed by an artificial nose. When we choose an artificial nose, we should take into account the volume and resistance of the available devices. We should also consider the mechanical effects of the artificial noses when setting mechanical ventilation and when assessing a patient's ability to breathe spontaneously.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating Humidity Recovery Efficiency of Currently Available Heat and Moisture Exchangers: A Respiratory System Model Study

OBJECTIVES To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. INTRODUCTION Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute h...

متن کامل

Heat and Moisture Exchangers and Humidification Efficacy in Pediatrics: Effects of Ventilator Settings and ETT Leakage

Heat and moisture exchangers (HMEs) have been increasingly used for humidification during mechanical ventilation in pediatric patients [1]. However, efficacy of HMEs in the pediatric population has not yet been fully evaluated and there is limited information in the literature regarding the effects of ventilator settings and endotracheal tube (ETT) leakage on the humidification performance of H...

متن کامل

Experimental study of nanofluid effects on heat transfer in closed cycle system in shell and tube heat exchangers at Isfahan power plant

The present study investigated the effect of distilled-water/ silver nanofluid on heat transfer in a closed cooling system of one of the electrical energy generation units at Isfahan power plant. The difference between this study and previous researches refers to silver properties which have a high thermal conductivity and is non-toxic, hydrophilic and eco-friendly. Distilled water/ silver ...

متن کامل

Experimental study of nanofluid effects on heat transfer in closed cycle system in shell and tube heat exchangers at Isfahan power plant

The present study investigated the effect of distilled-water/ silver nanofluid on heat transfer in a closed cooling system of one of the electrical energy generation units at Isfahan power plant. The difference between this study and previous researches refers to silver properties which have a high thermal conductivity and is non-toxic, hydrophilic and eco-friendly. Distilled water/ silver ...

متن کامل

Ventilatory changes during the use of heat and moisture exchangers in patients submitted to mechanical ventilation with support pressure and adjustments in ventilation parameters to compensate for these possible changes: a self-controlled intervention study in humans

OBJECTIVE To evaluate the possible changes in tidal volume, minute volume and respiratory rate caused by the use of a heat and moisture exchanger in patients receiving pressure support mechanical ventilation and to quantify the variation in pressure support required to compensate for the effect caused by the heat and moisture exchanger. METHODS Patients under invasive mechanical ventilation i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical Care

دوره 3  شماره 

صفحات  -

تاریخ انتشار 1999