Coronary artery bypass with the use of a magnetic distal anastomotic device: surgical technique and preliminary experience.

نویسندگان

  • Thanos Athanasiou
  • Hutan Ashrafian
  • Brian Glenville
  • Roberto Casula
چکیده

BACKGROUND At present there is little reported experience in the application of new technology in the performance of distal coronary anastomoses in the clinical setting. The aim of our study was to evaluate the feasibility of using the Ventrica magnetic vascular positioner (MVP) device for left internal thoracic artery (LITA)-to-left anterior descending (LAD) coronary anastomosis. METHODS We present our preliminary experience of the first 14 coronary artery cases performed in the United Kingdom from April 2003 to December 2003. The selection criteria, surgical technique, clinical outcome, advantages or disadvantages, and future implications are all discussed. RESULTS The device was used in 12 patients for LITA-to-LAD anastomosis and in 2 patients for the proximal anastomosis of a radial artery Y-graft from the LITA to the circumflex territories. The first 3 patients underwent coronary artery bypass graft with the use of cardiopulmonary bypass, and the remaining 9 underwent surgery performed using an off-pump coronary artery bypass technique. No mortality or device-related events were observed in these patients. The anastomosis time in our series was 5.6 +/- 1.99 minutes, and the blood loss was 914 +/- 234 mL. The mean length of stay was 5.8 +/- 1.16 days. CONCLUSION The MVP system is a novel distal coronary anastomotic device that is quick, simple, and effective, producing consistently reliable coronary anastomoses in a wide variety of coronary bypass procedures. Early results are encouraging, and further studies are required in order to evaluate long-term efficacy of this system in the rapidly changing world of coronary revascularization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

جراحی بای پس عروق کرونر بدون استفاده از ماشین قلب- ریه: روشی مطمئن برای ریواسکولاریزیشن کامل

In recent years off-pump coronary artery bypass surgery (OPCAB) has emerged as preferred method for revascularization of coronary arteries in relatively selected group of patients. Considering patients receiving incomplete revascularization need significantly higher postoperative catheterization and re-intervention (PTCA or CABG), we performed this study to identify safety and feasibility of th...

متن کامل

Distal anastomotic patency of the Cardica C-PORT(R) xA system versus the hand-sewn technique: a prospective randomized controlled study in patients undergoing coronary artery bypass grafting.

OBJECTIVES The C-Port® Distal Anastomosis Systems (Cardica, Inc., Redwood City, CA, USA) demonstrated favourable results in feasibility trials. However, distal vein anastomoses created with the C-Port® or C-Port xA® system have never been compared with hand-sewn distal vein anastomoses. The objective of this study was to compare distal end-to-side anastomoses facilitated with the C-Port xA® Sys...

متن کامل

Facilitated endoscopic beating heart coronary artery bypass grafting using a magnetic coupling device.

BACKGROUND Suturing of a coronary anastomosis in totally endoscopic coronary artery bypass grafting on the beating heart is technically demanding. The potential benefits of the endoscopic Magnetic Vascular Positioner device (Ventrica, Inc, Fremont, Calif) to facilitate construction of a coronary anastomosis in a closed chest environment were evaluated. METHODS Totally endoscopic coronary arte...

متن کامل

Early patency evaluation of new distal anastomotic device in internal mammary artery grafts using computed tomography angiography.

INTRODUCTION : Traditional coronary artery bypass grafting is performed using a hand sewn technique. The C-Port xA and Flex A anastomotic stapling devices (Cardica Inc., Redwood City, CA) were cleared by the Food and Drug Administration for use in distal coronary anastomoses in November 2006 and April 2007, respectively. They provide the ability to create a compliant, consistently reproducible,...

متن کامل

Major Leg Wound Complications After Saphenous Vein Harvest for Coronary Revascularization

Background: Major leg wound complications after coronary artery bypass graft procedures are infrequent and few are reported in the litrature.We present our experience in treating 30 patients with major leg wound complications after coronary revascularization procedures. Materials and Methods: A retrospective review of 2100 bypass procedures with saphenous veingraft performed over a 5-years p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The heart surgery forum

دوره 7 6  شماره 

صفحات  -