Thiopental and Phenytoin as Novel Ionophores for Potentiometric Determination of Lead (II) Ions
نویسندگان
چکیده
Two novel polymeric membrane sensors for the analysis of Pb(II) have been developed based on two therapeutic drugs, thiopental (TP) and phenytoin (PT) as two new ionophores and potassium tetrakis(p-chlorophenyl) borate (KTpClPB) as a lipophilic additive, in plasticized PVC membranes. The sensors show a Nernstian response for Pb(II) ions over the wide concentration ranges of 1×10(-2) - 7×10(-6) M and 1×10(-2) - 8×10(-6) M for the sensors based on thiopental and phenytoin, respectively. The proposed sensors have a fast response time and can be used for more than nine weeks without any considerable divergence in potentials. The sensors exhibit comparatively good selectivity with respect to alkaline, alkaline earth and some transition and heavy metal ions. They were employed for direct determination of lead in solder alloys and in galena rocks with a good agreement with the obtained results by atomic absorption spectroscopy.
منابع مشابه
Fabrication of new carbon paste electrodes based on gold nano-particles self-assembled to mercapto compounds as suitable ionophores for potentiometric determination of Copper ions
In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...
متن کاملDetermination of Chromium(III) and Magnesium(II) Ions in Pharmacological and Real Water Samples using Potentiometric Sensors based on Chitosan Schiff base Derivative as Green and Sensitive Ionophore
In the study, novel and sensitive carbon paste electrodes (CPEs) developed for thepotentiometric measurement of Cr(III) and Mg(II) ions in pharmacological and water samples.CPEs as indicator electrodes were prepared from a mixture of four components, includinggraphite powder, paraffin oil, multi-walled carbon nanotubes (MWCNTs), and a greenionophore (Chitosan Schiff base...
متن کاملNew Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions
A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...
متن کاملPolymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
متن کاملIon-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کامل