Comparison of nasal pressure transducer and thermistor for detection of respiratory events during polysomnography in children.

نویسندگان

  • Rohit Budhiraja
  • James L Goodwin
  • Sairam Parthasarathy
  • Stuart F Quan
چکیده

STUDY OBJECTIVES The results of small studies have suggested that a nasal-cannula pressure transducer has a higher sensitivity than a thermistor in detecting hypopneas and diagnosing sleep-disordered breathing in both adults and children. We compared a thermistor alone, and in conjunction with a pressure transducer, for detection of sleep-disordered breathing in children during in-home polysomnography. DESIGN Retrospective analysis of a subsample of a prospective cohort study. SETTING Students attending elementary school in the Tucson Unified School District. PARTICIPANTS A subsample of the Tucson Children's Assessment of Sleep Apnea study population. MEASUREMENTS AND RESULTS Polysomnographic recordings of 40 children (24 girls and 16 boys, mean age 9.2 +/- 1.7 years; range 6-11 years) were analyzed to compare the detection of sleep-disordered breathing events by 2 different methods of measuring airflow: thermistor alone and thermistor with nasal-cannula pressure transducer (transducer) used simultaneously. The transducer detected all the respiratory events detected by the thermistor, but the thermistor detected only 84% of the transducer-defined events. Consequently, the transducer-derived mean respiratory disturbance index was higher than that detected by the thermistor (7.0 +/- 3.8 vs 5.9 +/- 3.4, P < .001). The bias error between transducer respiratory disturbance index and thermistor respiratory disturbance index on a Bland-Altman plot was 1.08 (95% confidence interval, 0.8 - 1.4). There was good agreement between the thermistor and the transducer for making the diagnosis of sleep apnea using a cutoff of a respiratory disturbance index greater than 5 (kappa = 0.69). The quality of the tracings with the transducer was comparable to that of the thermistor, but the transducer dislodged more frequently. CONCLUSION The use of a nasal transducer in conjunction with a thermistor was more sensitive than the thermistor alone in detecting sleep-disordered breathing in children during unattended polysomnography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of upper airway resistance syndrome using a nasal cannula/pressure transducer.

STUDY OBJECTIVES To determine the diagnostic utility of a nasal cannula/pressure transducer (NC), in comparison to thermistor (TH), during routine, clinical nocturnal polysomnography (NPSG). DESIGN We analyzed the respiratory arousal index (RAI) using TH (RAI-TH) or NC (RAI-NC) in patients with suspected sleep-disordered breathing (SDB). SETTING Sleep disorders center of a university-affili...

متن کامل

Nasal prongs in the detection of sleep-related disordered breathing in the sleep apnoea/hypopnoea syndrome.

Conventional systems to monitor oronasal flow in sleep studies have traditionally relied on a thermistor signal. Our study was designed to verify whether nasal prongs (NP) connected to a pressure transducer could improve respiratory events detection in patients with sleep apnoea/hypopnoea syndrome (SAHS) compared to traditional systems. Sleep episodes from a 2 h conventional polysomnographic re...

متن کامل

Performance of nasal prongs in sleep studies : spectrum of flow-related events.

OBJECTIVES The use of nasal prongs connected to a pressure transducer is a noninvasive, sensitive method to detect respiratory events, and can be easily implemented in routine sleep studies. Moreover, its good time response allows the detection of several flow-related phenomena of high interest, in addition to apnea and hypopnea. The aims of the study were to examine the quality and performance...

متن کامل

Breathing patterns in prepubertal children with sleep-related breathing disorders.

OBJECTIVE To investigate abnormal breathing patterns during sleep in prepubertal children using nonstandard polysomnographic patterns in association with an apnea-hypopnea scoring technique. PATIENTS AND METHODS Study participants included 400 children with suspected sleep-related breathing disorders and 60 control children. We analyzed clinical signs and symptoms at entry into the study and ...

متن کامل

Physiologic Effects of Intra-nasal Sedation with Midazolam and Ketamine in 3-6 Years old Uncooperative Children

  Objective: Several medications have been used for sedation in children in dentistry and intra-nasal route has been reported to be an efficient way regarding patient cooperation. The aim of the present study was to compare the changes in physiologic parameters following intra-nasal midazolam and ketamine administration.   Methods: In this randomized cross-over double-blind trial, 17 uncooperat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sleep

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 2005