Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.
نویسندگان
چکیده
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contemporary alumina-on-alumina total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum duration of follow-up of five years. METHODS We evaluated the results of a consecutive series of 100 primary alumina-on-alumina total hip arthroplasties that had been performed with use of a metal-backed socket and a cementless stem in eighty-four patients. All of the patients were sixty-five years of age or younger (mean age, forty-one years), and a single surgeon performed all of the procedures. After a minimum duration of follow-up of sixty months, one patient (one hip) had died and four patients (six hips) had been lost to follow-up, leaving a total of seventy-nine patients (ninety-three hips) available for study. All of these patients were evaluated clinically and radiographically with special attention to wear, periprosthetic osteolysis, and ceramic failure. RESULTS The mean Harris hip score was 97 points at the time of the latest follow-up evaluation. All prostheses demonstrated radiographic evidence of bone ingrowth. No implant was loose radiographically, and no implant was revised. Ceramic wear was not detectable in the thirty-seven hips in which the femoral head could be differentiated from the cup on radiographs. Periprosthetic osteolysis was not observed in any hip. A fracture of the alumina femoral head and a peripheral chip fracture of the alumina insert occurred in one hip following a motor-vehicle accident. CONCLUSIONS The results of contemporary alumina-on-alumina total hip arthroplasty with a metal-backed socket and a cementless stem were encouraging after a minimum duration of follow-up of five years. We believe that these improved alumina-on-alumina bearing implants offer a promising option for younger, active patients.
منابع مشابه
Alumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report.
We previously reported the five-to-six-year results of the use of third-generation alumina-on-alumina bearings in a consecutive series of 100 primary cementless total hip arthroplasties. This report presents the longer-term outcomes of these same bearings, at a minimum of ten years postoperatively. Eighty-six of eighty-eight hips available for the study retained the original bearings at the tim...
متن کاملIsolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty.
BACKGROUND While most reports of component fracture following alumina-on-alumina total hip arthroplasty have involved the acetabular liner, few have involved fracture of the alumina femoral head. In the present multicenter study, we investigated ceramic head fractures in a cohort of patients who underwent third-generation alumina-on-alumina total hip arthroplasty. METHODS We performed a retro...
متن کاملIn vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up
BACKGROUND Zirconia was introduced as an alternative to alumina for use in the femoral head. The yttria stabilized zirconia material was improved by adding alumina. We evaluated highly cross-linked polyethylene wear performance of zirconia in total hip arthroplasty. The hypothesis was that alumina stabilized zirconia could decrease highly cross-linked polyethylene wear. METHODS Highly cross-l...
متن کاملLow-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report.
We report the results of our continued review of 11 total hip arthroplasties using 22.225 mm alumina ceramic femoral heads on a Charnley flanged stem, articulating with chemically cross-linked polyethylene. There was an initial bedding-in of up to 0.41 mm at the articular surface in the first two years. This had not progressed further, at a minimum follow-up of 15 years. Radiographically no fem...
متن کاملEffect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina.
We examined the behaviour of alumina ceramic heads in 156 cemented total hip arthroplasties, at a minimum follow-up of eight years. They were divided into three groups according to the size of the femoral head; 22, 26, and 28 mm. We measured polyethylene wear radiologically using a computer-aided technique. The linear wear rate of polyethylene sockets for the 28 mm heads was high (0.156 mm/year...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 87 3 شماره
صفحات -
تاریخ انتشار 2005