Robot assisted Neuronavigation and Stereotactic Neurosurgery Suite
ثبت نشده
چکیده
An initiative is undertaken by Bhabha Atomic Research Centre to extend affordable high quality neurosurgical practice in India. This automates the frameless Stereotaxy using a high precision 6 DOF Parallel Kinematic Mechanism (6D PKM) based Robot and a Surgical Coordinate Measuring Mechanism (SCMM). The system provides high accuracy as well as high patient comfort level as compared to conventional existing practices in neurosurgery.
منابع مشابه
Principles of Neuronavigation
Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...
متن کاملRobotics in neurosurgery.
Technological developments in imaging guidance, intraoperative imaging, and microscopy have pushed neurosurgeons to the limits of their dexterity and stamina. The introduction of robotically assisted surgery has provided surgeons with improved ergonomics and enhanced visualization, dexterity, and haptic capabilities. This article provides a historical perspective on neurosurgical robots, includ...
متن کاملFrameless stereotactic cerebral biopsy: our experience in 296 cases.
AIMS To evaluate the reliability, safety and accuracy of a the frameless stereotactic system in our clinical series and the differences between head fixation by means of a standard Mayfield head holder and the pinless FESS frame, and to evaluate the usefulness of biopsy targeting on the basis of magnetic resonance spectroscopy (MRS) data. METHODS The spectroscopic analysis was used to facilit...
متن کاملComparison of Neuronavigation and Frame-Based Stereotactic Systems in Implanting Epileptic Depth Electrodes.
AIM To investigate the application of neuronavigation in the implantation of depth electrodes in patients with epilepsy. MATERIAL AND METHODS Thirty-six patients with epilepsy who were implanted with depth electrodes using neuronavigation were assessed for accuracy of implantation and associated complications. RESULTS In the imaging navigation group, patients were implanted with 2-14 depth ...
متن کاملComparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation.
OBJECT The objective of this study was to compare the accuracy of 3 methods of ventricular catheter placement during CSF shunt operations: the freehand technique using surface anatomy, ultrasonic guidance, and stereotactic neuronavigation. METHODS This retrospective cohort study included all patients from a single institution who underwent a ventricular CSF shunting procedure in which a new v...
متن کامل