A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital Capacity
نویسندگان
چکیده
BACKGROUND Several recent studies have suggested that 1 minus-forced expiratory volume expired in 3 seconds / forced vital capacity (1-FEV3/FVC) may be an indicator of distal airway obstruction and a promising measure to evaluate small airways dysfunction. AIMS To investigate the associations of 1-FEV3/FVC with the spirometric measures and lung volumes that assess small airways dysfunction and reflects hyperinflation and air trapping. STUDY DESIGN Retrospective cross-sectional study. METHODS Retrospective assessment of a total of 1110 cases who underwent body plethysmographic lung volume estimations between a time span from 2005 to 2012. Patients were assigned into two groups: firstly by FEV1/FVC (FEV1/FVC <70% vs. FEV1/FVC ≥70%); secondly by FEV3/FVC < lower limits of normal (LLN) (FEV3/FVC < LLN vs. FEV3/FVC ≥ LLN). Spirometric indices and lung volumes measured by whole-body plethysmography were compared in groups. Also the correlation of spirometric indices with measured lung volumes were assessed in the whole-study population and in subgroups stratified according to FEV1/FVC and FEV3/FVC. RESULTS Six hundred seven (54.7%) were male and 503 (45.3%) were female, with a mean age of 52.5±15.6 years. Mean FEV3/FVC and 1-FEV3/FVC were 87.05%, 12.95%, respectively. The mean 1-FEV3/FVC was 4.9% in the FEV1/FVC ≥70% group (n=644) vs. 24.1% in the FEV1/FVC <70% group (n=466). A positive correlation was found between 1-FEV3/FVC and residual volume (r=0.70; p<0.0001), functional residual capacity-pleth (r=0.61; p<0.0001), and total lung capacity (r=0.47; p<0.0001). 1-FEV3/FVC was negatively correlated with forced expiratory flow25-75 (r=-0.84; p<0.0001). The upper limit of 95% confidence interval for 1-FEV3/FVC was 13.7%. 1-FEV3/FVC showed significant correlations with parameters of air trapping and hyperinflation measured by whole-body plethysmography. Importantly, these correlations were higher in study participants with FEV1/FVC <70% or FEV3/FVC < LLN compared to those with FEV1/FVC ≥70% or FEV3/FVC ≥ LLN, respectively. CONCLUSION 1-FEV3/FVC can be easily calculated from routine spirometric measurements. 1-FEV3/FVC is a promising marker of air trapping and hyperinflation. We suggest that 1-FEV3/FVC is complementary to FEV1/FVC and recommend clinicians to routinely report and evaluate together with FEV1/FVC during spirometry.
منابع مشابه
Air Trapping: A Cause of Heterogeneous Attenuation
Purpose: To investigate important factors affecting the frequency of air trapping through observation of normal lung attenuation, and propose a cause of heterogeneous attenuation. Materials and Methods: In this ethical committee-approved study, a total of 109 patients (30 males, 79 females; mean age, 58.2 years; range, 27 81 years) were included. All patients had undergone inspiratory and expir...
متن کاملCT Air Trapping Is Independently Associated with Lung Function Reduction over Time
PURPOSE We aimed to study the association between lung function decline and quantitative computed tomography (CT) air trapping. MATERIALS AND METHODS Current and former heavy smokers in a lung cancer screening trial underwent volumetric low-dose CT in inspiration and expiration. Spirometry was obtained at baseline and after 3 years. The expiratory to inspiratory ratio of mean lung density (E/...
متن کاملEffects of beclomethasone/formoterol fixed combination on lung hyperinflation and dyspnea in COPD patients
BACKGROUND Chronic obstructive pulmonary disease (COPD) is a common disease characterized by airflow obstruction and lung hyperinflation leading to dyspnea and exercise capacity limitation. OBJECTIVES The present study was designed to evaluate whether an extra-fine combination of beclomethasone and formoterol (BDP/F) was effective in reducing air trapping in COPD patients with hyperinflation....
متن کاملTime-varying Changes in Pulmonary Function with Exposure to Prolonged Sitting
OBJECTIVES The purpose of this study was to quantify the time-varying changes in pulmonary function with exposure to prolonged sitting. METHODS Twenty-one healthy volunteers were recruited. The pulmonary function of all participants was measured three times in order to assess changes over time; pulmonary function was measured before sitting, after participants had been seated for 1 hour, and ...
متن کاملDNAH5 is associated with total lung capacity in chronic obstructive pulmonary disease
BACKGROUND Chronic obstructive pulmonary disease (COPD) is characterized by expiratory flow limitation, causing air trapping and lung hyperinflation. Hyperinflation leads to reduced exercise tolerance and poor quality of life in COPD patients. Total lung capacity (TLC) is an indicator of hyperinflation particularly in subjects with moderate-to-severe airflow obstruction. The aim of our study wa...
متن کامل