Effect of temperature on composite polymerization stress and degree of conversion.

نویسندگان

  • Fernanda C Calheiros
  • Márcia Daronch
  • Frederick A Rueggeberg
  • Roberto R Braga
چکیده

OBJECTIVE To test the following hypotheses: (1) degree of conversion (DC) and polymerization stress (PS) increase with composite temperature (2) reduced light-exposure applied to pre-heated composites produces similar conversion as room temperature with decreased PS. METHODS Composite specimens (diameter: 5mm, height: 2mm) were tested isothermally at 22°C (control), 40°C, and 60°C using light-exposures of 5 or 20s (control). DC was accessed 5min after light initiation by FTIR at the specimen bottom surface. Maximum and final PS were determined, also isothermally, for 5min on a universal testing machine. Non-isothermal stress was also measured with composite maintained at 22°C or 60°C, and irradiated for 20s at 30°C. Data were analyzed using two-way ANOVA/Tukey and Student's t-test (α=5%). RESULTS Both DC and isothermal maximum stress increased with temperature (p<0.001) and exposure duration (p<0.001). Isothermal maximum/final stress (MPa) were 3.4±2.0b/3.4±2.0A (22°C), 3.7±1.5b/3.6±1.4A (40°C) and 5.1±2.0a/4.0±1.6A (60°C). Conversion values (%) were 39.2±7.1c (22°C), 50.0±5.4b (40°C) and 58.5±5.7a (60°C). The reduction of light exposure duration (from 20s to 5s) with pre-heated composite yielded the same or significantly higher conversion (%) than control (22°C, 20s/control: 45.4±1.8b, 40°C, 5s s: 45.1±0.5b, 60°C, 5s s: 53.7±2.7a, p<0.01). Non-Isothermal conditions showed significantly higher stress for 60°C than 22°C (in MPa, maximum: 4.7±0.5 and 3.7±0.4, final: 4.6±0.6 and 3.6±0.4, respectively). CLINICAL SIGNIFICANCE Increasing composite temperature allows for reduced exposure duration and lower polymerization stress (both maximum and final) while maintaining or increasing degree of conversion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه گیری میزان انقباض پلیمریزاسیون خطی در کامپوزیت ایرانی ایده آل ماکو (IDM) لایت کیور

 Polymerization shrinkage of light cure composite resins causes many complications in conservative and esthetic restorations. The objective of this in-vitro study was to evaluate the polymerization shrinkage, degree of conversion and the amount of filler in IDM and tetric ceram composites. Ten disk shaped, uncured specimens (8mm×1.547mm) of each composite were placed on glass slide in the cente...

متن کامل

تأثیر نوع دستگاه تابشی و روش تابش نور بر درجه تبدیل دو نوع کامپوزیت نوری

Background and Aim: Halogen lamp is the commonly used light source for composite photo polymerization. Recently, high power halogen lamps, LED and plasma arc are introduced for improving the polymerization. The aim of this study was to investigate the effect of conventional and high power halogen lamps and LED light curing unit on degree of conversion of two different composite resins.Materials...

متن کامل

The Effect of Standard and Extended Curing Time in Different Distances on Composite’s Degree of Conversion

Introduction: The aim of this study was to in-vestigate the effect of irradiation duration and distance of light tip to prepared samples in two different light curing unites on the degree of conversion of resin composite. Materials and Methods: Conventional halogen and blue Light emitting diode (LED) units were used for polymerization of an Opalis resin com-posite. The conversion measurements w...

متن کامل

Effect of LED and Argon Laser on Degree of Conversion and Temperature Rise of Hybrid and Low Shrinkage Composite Resins

OBJECTIVES Different light curing units are used for polymerization of composite resins. The aim of this study was to evaluate the degree of conversion (DC) and temperature rise in hybrid and low shrinkage composite resins cured by LED and Argon Laser curing lights. MATERIALS AND METHODS DC was measured using FTIR spectroscopy. For measuring temperature rise, composite resin samples were plac...

متن کامل

Synthesis of Polybutadiene Nanoparticles via Emulsion Polymerization: Effect of Reaction Temperature on the Polymer Microstructure, Particle Size and Reaction Kinetics

Polybutadiene nanoparticles were synthesized via batch emulsion polymerization of butadiene in the presence of potassium persulfate, disproportionate rosinate potassium cation and t-dodecyl mercaptane as initiator, emulsifier and chain transfer agent, respectively. Polymerization reaction was performed at different temperatures (60, 70 and 80 °C). Conversion was measured at the various time int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 2014