Evaluation of the Ambu CPAP system.
نویسنده
چکیده
We have assessed a Venturi driven device for delivering continuous positive airway pressure (CPAP) using a reservoir bag and expiratory valve under conditions of continuous flow and simulated spontaneous breathing. The system performed well and was economical, consuming only 3.5 litre min-1 of fresh gas. One Venturi was partially blocked and performed inadequately, but the function of a second one was close to the manufacturer's specification (inspired oxygen 33%, flow 20 litre min-1 against end-expiratory pressures of 0-1.8 kPa). Compliance curves for two reservoir bags (new and old) were defined; these showed that compliance increased as the pressure in the circuit increased. The characteristics of the expiratory valve approached those of a threshold resistor. Small fluctuations in airway pressure occurred at all settings of CPAP and decreased with the increasing compliance of the circuit at higher values of CPAP. The method provided to monitor the airway pressure was inaccurate and overestimated the true pressure by 20% at pressures greater than 1 kPa.
منابع مشابه
Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures
OBJECTIVES To compare the efficacy and performance of the pediatric Ambu AuraOnce (Ambu AO) mask (Ambu, Copenhagen, Denmark) and i-gel mask (Intersurgical Ltd., Wokingham, United Kingdom). Methods: From May 2015 to September 2016, 112 patients, 0-14 years old, underwent elective surgery at a tertiary university hospital (Riyadh, Saudi Arabia). They were randomly assigned to the Ambu AO or i-gel...
متن کاملThe Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP) in Premature Neonates: A Cross-Over Clinical Trial Study
Background The most common cause of admission to neonatal intensive care units (NICU) is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP). Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to ...
متن کاملدرمان زودرس با Nasal CPAP در نوزادان نارس با سندرم دیسترس تنفسی
Background: Respiratory distress syndrome (RDS) is a major cause of mortality among premature neonates. The present study was conducted to find out whether early nasal CPAP therapy could eliminate the need for mechanical ventilation in premature neonates with RDS. Materials and methods: For this clinical trial, premature neonates with RDS during the first 6 hours following the delivery were as...
متن کاملComparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates
Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled...
متن کاملRandomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I-IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 62 3 شماره
صفحات -
تاریخ انتشار 1989