Assessment of Adaptive Rate Response Provided by Accelerometer, Minute Ventilation and Dual Sensor Compared with Normal Sinus Rhythm During Exercise: A Self-controlled Study in Chronotropically Competent Subjects

نویسندگان

  • Yuanyuan Cao
  • Yiqun Zhang
  • Yangang Su
  • Jin Bai
  • Wei Wang
  • Junbo Ge
چکیده

BACKGROUND Dual sensor (DS) for rate adaption was supposed to be more physiological. To evaluate its superiority, the DS (accelerometer [ACC] and minute ventilation [MV]) and normal sinus rate response were compared in a self-controlled way during exercise treadmill testing. METHODS This self-controlled study was performed in atrioventricular block patients with normal sinus function who met the indications of pacemaker implant. Twenty-one patients came to the 1-month follow-up visit. Patients performed a treadmill test 1-month post implant while programmed in DDDR and sensor passive mode. For these patients, sensor response factors were left at default settings (ACC = 8, MV = 3) and sensor indicated rates (SIRs) for DS, ACC and MV sensor were retrieved from the pacemaker memories, along with measured sinus node (SN) rates from the beginning to 1-minute after the end of the treadmill test, and compared among study groups. Repeated measures analysis of variance and profile analysis, as well as variance analysis of randomized block designs, were used for statistical analysis. RESULTS Fifteen patients (15/21) were determined to be chronotropically competent. The mean differences between DS SIRs and intrinsic sinus rates during treadmill testing were smaller than those for ACC and MV sensor (mean difference between SIR and SN rate: ACC vs. SN, MV vs. SN, DS vs. SN, respectively, 34.84, 17.60, 16.15 beats/min), though no sensors could mimic sinus rates under the default settings for sensor response factor (ACC vs. SN P-adjusted < 0.001; MV vs. SN P-adjusted = 0.002; DS vs. SN P-adjusted = 0.005). However, both in the range of 1 st minute and first 3 minutes of exercise, only the DS SIR profile did not differ from sinus rates (P-adjusted = 0.09, 0.90, respectively). CONCLUSIONS The DS under default settings provides more physiological rate response during physical activity than the corresponding single sensors (ACC or MV sensor). Further study is needed to determine if individual optimization would further improve adaptive performance of the DS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed Loop Stimulation and Evaluation of the Effect of the Autonomic Nervous System Using Heart Rate Variability

Rate-Responsive Pacemakers Rate-responsive pacemakers are widely used to treat chronotropic incompetence as well as complete atrioventricular (AV) block or sinus node disease. Of the several sensor concepts that have been evaluated since 1980, the activity sensor (accelerometer) and two physiologic models (minute ventilation and QT interval) have been predominantly used in clinical practice. So...

متن کامل

Chronotropic incompetence in Chagas disease: effectiveness of blended sensor (volume/minute and accelerometer)

INTRODUCTION Technological progress of pacemakers has allowed the association of two or more sensors in one heart rate system response. The accelerometer sensor measures the intensity of the activity; it has a relatively rapid response to the beginning of it, however, it may present insufficient response to less strenuous or of less impact exercise. The minute ventilation sensor changes the pac...

متن کامل

بررسی تأثیر موسیقی بر پاسخ های قلبی- تنفسی و شاخص درک تقلای مردان ورزشکار هنگام فعالیت ورزشی فزاینده

  Background: The purpose of this study was to study the effect of fast music rhythm on cardio- respiratory responses and perceived exertion rate during incremental exercise in athletic men.   Methods : Ten athlete males (age: 22 2.44 yr, height: 176 ± 6.72 cm, weight: 69.4 ±4.65 kg), voluntarily performed Bruce protocol until exhaustion with fast music condition, and cross-over format, with 72...

متن کامل

Comparison of the normal sinus node with seven types of rate responsive pacemaker during everyday activity.

The heart rate response of 59 patients aged 17-79 years implanted with seven different types of rate responsive pacemakers was evaluated during graded exercise treadmill testing and during standardised daily activities. The heart rate response in patients with pacemakers was compared with the chronotropic response in 20 healthy controls of similar age and sex distribution who performed identica...

متن کامل

Atrial adaptive rate pacing in sick sinus syndrome: effects on exercise capacity and arrhythmias.

OBJECTIVE To test the hypotheses that adaptive rate atrial (AAIR) pacing: significantly increases maximal exercise capacity, and results in significant suppression of supraventricular and ventricular arrhythmia compared with fixed rate atrial (AAI) pacing. DESIGN Prospective, randomised, single blind, crossover study with maximal treadmill exercise testing and 24 hour ambulatory electrocardio...

متن کامل