Evaluation of dosimetry and excess seeds in permanent brachytherapy using a modified hybrid method: a single-institution experience

نویسندگان

  • Kana Kobayashi
  • Koji Okihara
  • Tsuyoshi Iwata
  • Norihiro Aibe
  • Naohiro Kodani
  • Takuji Tsubokura
  • Kazumi Kamoi
  • Tsuneharu Miki
  • Hideya Yamazaki
چکیده

Permanent prostate brachytherapy is frequently performed worldwide, and many studies have demonstrated its favorable outcomes. Implant seeds used in this procedure contain a precise amount of radionuclide and are completely sealed. Because these seeds are not manufactured in Japan, they are expensive (6300 yen per seed) and therefore need careful management as a radioisotope. The proper implantation technique requires considerable procedure time, good dosimetric outcomes and simple radioactive isotope management. To evaluate the modified hybrid interactive technique based on these considerations, we assessed 313 patients who underwent hybrid interactive brachytherapy without additional external beam radiotherapy. We evaluated the duration of the procedure, dosimetric factors and the total number of excess seeds. The dosimetric results from computed tomography on Day 30 of follow-up were: 172 Gy (range 130-194 Gy) for pD90, 97.8% (83.5-100%) for pV100, 54.6% (27.5-82.4%) for pV150, 164 Gy (120-220 Gy) for uD90, 194 Gy (126-245 Gy) for uD30, 210 Gy (156-290 Gy) for uD5, 0.02 ml (0-1.2 ml) for rV100 and 0 ml (0-0.2 ml) for rV150. The number of excess seeds was determined by subtracting the number of implanted seeds from the expected number of seeds calculated from previously proposed nomograms. As per our method, nine excess seeds were used for two patients, whereas using the nomograms, the number of excess seeds was approximately eight per patient. Our modified hybrid interactive technique reduced the number of excess seeds while maintaining treatment quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective: The present study aims to modify source strength for different configurations of 125I and 103...

متن کامل

The use of nomograms in LDR-HDR prostate brachytherapy

PURPOSE The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LD...

متن کامل

A simple technique for the generation of institution-specific nomograms for permanent prostate cancer brachytherapy

PURPOSE Nomograms once had a vital role in prostate brachytherapy practice. Although some of their functions have been assumed by computerized dosimetry, many programs still find them useful to determine the number and strength of seeds to be ordered in advance of the implant. As it has been demonstrated that brachytherapists differ in their implant practices and preferences (in regard to seed ...

متن کامل

Inverse planning optimization for hybrid prostate permanent‐seed implant brachytherapy plans using two source strengths

The purpose is to demonstrate the ability to generate clinically acceptable prostate permanent seed implant plans using two seed types which are identical except for their activity. The IPSA inverse planning algorithms were modified to include multiple dose matrices for the calculation of dose from different sources, and a selection algorithm was implemented to allow for the swapping of source ...

متن کامل

Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry

Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013