Improvements of U-pipe Borehole Heat Exchangers

نویسنده

  • José Acuña
چکیده

3 PREFACE 4 ACKNOWLEDGEMENTS 5 PUBLICATIONS 6 ABBREVIATIONS AND NOMENCLATURE 7 TABLE OF CONTENTS 10 INDEX OF FIGURES 11 INDEX OF TABLES 14 1 INTRODUCTION – BASIC CONCEPTS 15 1.1 GROUND SOURCE HEAT PUMPS 15 1.2 THERMAL PROCESSES IN THE GROUND 18 1.3 SECONDARY WORKING FLUID FLOW 20 1.3.1 Hydrodynamic considerations 21 1.3.2 Thermal considerations 21 1.4 THERMAL RESISTANCES IN BHES 23 1.5 THERMAL RESPONSE TEST 26 1.6 BOREHOLE HEAT EXCHANGERS-STATE OF THE ART 29 1.6.1 U-pipe BHEs 30 1.6.2 Coaxial BHEs 32 1.7 DISTRIBUTED TEMPERATURE MEASUREMENTS 33 2 EXPERIENCES WITH U-PIPE BHES 39 2.1 DESCRIPTION OF THE INSTALLATION 39 2.2 TEMPERATURES DURING HEAT PUMP OPERATION 43 2.3 DISTRIBUTED THERMAL RESPONSE TEST 50 2.4 DISTRIBUTED PRESSURE MEASUREMENTS 57 3 EXPERIENCES WITH ALTERNATIVE U-PIPE BHES 61 3.1 THEORETICAL EVALUATION 62 3.2 EXPERIMENTAL EVALUATION 67 4 EXPERIENCES WITH COAXIAL BHES 76 4.1 AN ANNULAR COAXIAL BHE FIRST PROTOTYPE 76 4.2 COAXIAL PROTOTYPE WITH FIVE EXTERNAL FLOW CHANNELS 80 5 CONCLUSIONS 90 6 REFERENCES 95

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An extended two-dimensional borehole heat exchanger model for simulation of short and medium timescale thermal response

Common approaches to the simulation of Borehole Heat Exchangers (BHEs) assume heat transfer in circulating fluid and grout to be in a quasi-steady state and ignore fluctuations in fluid temperature due to transport of the fluid around the U-tube loop. Such effects have been shown to have an impact on peak temperatures and hence operation of heat pumps systems when short time scales are consider...

متن کامل

Distributed Thermal Response Test on a U-pipe Borehole Heat Exchanger

In a Distributed Thermal Response Test (DTRT) the ground thermal conductivity and borehole thermal resistance are determined at many instances along the borehole. Here, such a test is carried out at a 260 m deep water filled energy well, equipped with a U-pipe borehole heat exchanger, containing an aqueous solution of ethanol as working fluid. Distributed temperature measurements are carried ou...

متن کامل

Novel Wireless Sensor System for Dynamic Characterization of Borehole Heat Exchangers

The design and field test of a novel sensor system based in autonomous wireless sensors to measure the temperature of the heat transfer fluid along a borehole heat exchanger (BHE) is presented. The system, by means of two special valves, inserts and extracts miniaturized wireless sensors inside the pipes of the borehole, which are carried by the thermal fluid. Each sensor is embedded in a small...

متن کامل

Enhancements of an Integrated Simulation Tool for Ground- Source Heat Pump System Design and Energy Analysis

Ground-source heat pump (GSHP) utilizes the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. GSHP systems are generally comprised of water source heat pumps and ground heat exchangers (GHX). Vertical closed-loop GHX is used predominantly in commercial and institutional applications. Closed loop GHX consists of a...

متن کامل

Improvement in Modeling of Heat Transfer in Vertical Ground Heat Exchangers

The heat transfer model of vertical ground heat exchangers for ground-source heat pump systems is discussed. An explicit solution of a finite line-source model has been derived to better describe temperature response of boreholes for long time steps, which can be easily incorporated into computer programs for thermal analysis of ground heat exchangers. A quasi-three-dimensional model is also pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010