Optimization of wavelength range and data interval in chemometric analysis of complex pharmaceutical mixtures☆
نویسندگان
چکیده
The performance of different chemometric approaches was evaluated in the spectrophotometric determination of pharmaceutical mixtures characterized by having the amount of components with a very high ratio. Principal component regression (PCR), partial least squares with one dependent variable (PLS1) or multi-dependent variables (PLS2), and multivariate curve resolution (MCR) were applied to the spectral data of a ternary mixture containing paracetamol, sodium ascorbate and chlorpheniramine (150:140:1, m/m/m), and a quaternary mixture containing paracetamol, caffeine, phenylephrine and chlorpheniramine (125:6. 25:1.25:1, m/m/m/m). The UV spectra of the calibration samples in the range of 200-320 nm were pre-treated by removing noise and useless data, and the wavelength regions having the most useful analytical information were selected using the regression coefficients calculated in the multivariate modeling. All the defined chemometric models were validated on external sample sets and then applied to commercial pharmaceutical formulations. Different data intervals, fixed at 0.5, 1.0, and 2.0 point/nm, were tested to optimize the prediction ability of the models. The best results were obtained using the PLS1calibration models and the quantification of the species of a lower amount was significantly improved by adopting 0.5 data interval, which showed accuracy between 94.24% and 107.76%.
منابع مشابه
Thermodynamic Study of the Ion-Pair Complexation Equilibria of Dye and Surfactant by Spectral Titration and Chemometric Analysis
Surfactant-dye interactions are very important in chemical and dyeing processes. The dyes interact strongly with surfactant and show new spectrophotometric properties, so the UV-vis absorption spectrophotometric method has been used to study this process and extract some thermodynamic parameters. In this work, the association equilibrium between ionic dyes and ionic surfactant were studied by a...
متن کاملApplication of Chemometrics in Simultaneous Spectrophotometric Quantification of Etophylline and Theophylline: The Drugs with Same Chromophore
Chemometric techniques in spectral analysis have gained importance in the quality control of the drugs mixtures and pharmaceutical formulations containing two or more drugs with overlapping spectra. Since theophylline and etophylline have common chromophore, they cannot be analyzed simultaneously using conventional UV methods. Simultaneous spectrophotometric determination of etophylline and th...
متن کاملThermodynamic Characterization of the Aggregation Phenomena of SafranineT by Spectral Titration and Chemometric Analysis
The dimerization constants of Safranine T have been determined by studying the dependence of its absorption spectra on the temperature in the range 30–70 ◦C at different total concentrations of Safranine T (1.03×10−5, 1.44×10−5 and 1.73×10−5 M). The monomer–dimer equilibrium of Safranine T has been determined by applying MCR-ALS method on the absorpti...
متن کاملSimultaneous Spectrophotometric Determination of Ezetimibe and Simvastatin in Pharmaceutical Preparations Using Chemometric Techniques
Two spectrophotometric methods are described for the simultaneous determination of ezetimibe (EZE) and simvastatin (SIM) in pharmaceutical preparations. The obtained data was evaluated by using two different chemometric techniques, Principal Component Regression (PCR) and Partial Least-Squares (PLS-1). In these techniques, the concentration data matrix was prepared by using the mixtures contain...
متن کاملChemometric Simultaneous Estimation of Clopidogrel Bisulphate and Aspirin from Combined Dosage Form
Two chemometric methods, inverse least square and classical least square, were applied to simultaneous assay of clopidogrel bisulphate and aspirin in their combined dosage tablet formulation. Twelve mixed solutions were prepared for the chemometric calibration as training set and 10 mixed solutions were prepared as validation set. The absorbance data matrix was obtained by measuring the absorba...
متن کامل