Determination of imidacloprid in water samples via photochemically induced fluorescence and second-order multivariate calibration.

نویسندگان

  • Edwar Fuentes
  • Camila Cid
  • María E Báez
چکیده

This paper presents a new method for the determination of imidacloprid in water samples; one of the most widely used neonicotinoid pesticides in the farming industry. The method is based on the measurement of excitation-emission spectra of photo-induced fluorescence (PIF-EEMs) associated with second-order multivariate calibration with a parallel factor analysis (PARAFAC) and unfolded partial least squares coupled to residual bilinearization (U-PLS/RBL). The second order advantage permitted the determination of imidacloprid in the presence of potential interferences, which also shows photo-induced fluorescence (other pesticides and/or unexpected compounds of the real samples). The photoreaction was performed in 100-μl disposable micropipettes. As a preliminary step, solid phase extraction on C18 (SPE-C18) was applied to concentrate the analyte and diminish the limit of detection. The LOD was approximately 1 ng mL(-1), which is suitable for detecting imidacloprid in water according to the guidelines established in North America and Europe. The PIF-EEMs coupled to PARAFAC or U-PLS/RBL was successfully applied for the determination of imidacloprid in different real water samples, with an average recovery of 101±10%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coupling Second-Order Excitation-Emission Spectrofluorimetric Data with Standard Addition method to Quantify Carvedilol in Real Samples

Prediction using pure standards is expected to be biased whenever the slope of the calibration is affected by the presence of sample matrix. Moreover, in the presence of unknown spectral interferents, first-order algorithms like partial least squares cannot be used. In this study, a method for determination of carvedilol (CAR) in tablet and urine samples is proposed by excitation-emission fluor...

متن کامل

Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data

Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...

متن کامل

Photochemically induced fluorimetric detection of tianeptine and some of its metabolites. Application to pharmaceutical preparation.

The photochemically induced fluorescence (PIF) properties of tianeptine and some of its metabolites were investigated in acidic (pH 2.3) water-alcohol mixtures at room temperature. Two PIF methods were developed, including bulk solution and flow injection analysis (FIA). Linear calibration plots were established over a concentration range of more than one order of magnitude. Limits of detection...

متن کامل

Development and application of a new sensitive spectrophotometric-multivariate calibration method to the simultaneous determination of hydrazine and acetylhydrazine using silver nanoparticles

In this paper, multivariate calibration methods of partial least squares (PLS) and principle component regression (PCR) were investigated in simultaneously determination of hydrazine (HZ) and acetylhydrazine (AHZ). The aforementioned methods are based on formation of the silver nanoparticles (AgNPs) from the reaction of HZ and AHZ with Ag+ ions as oxidizing agent in the presence of citrate ions...

متن کامل

Simultaneous spectrophotometric determination of lidocaine and hydrocortisone acetate in pharmaceutical preparations by multivariate calibration methods

The multivariate calibration method, partial least square regression (PLS) was applied for thesimultaneous spectrophotometric determination of Lidocaine (LID) and Hydrocortisone acetate(HCA) in their mixtures. The parameters of chemometric technique were optimized and theproposed method was validated with synthetic samples and applied to analyze these drugs inpharmaceutical products with good a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 134  شماره 

صفحات  -

تاریخ انتشار 2015