Standardization of Fractional Flow Reserve Measurements.

نویسندگان

  • Gabor G Toth
  • Nils P Johnson
  • Allen Jeremias
  • Mariano Pellicano
  • Pascal Vranckx
  • William F Fearon
  • Emanuele Barbato
  • Morton J Kern
  • Nico H J Pijls
  • Bernard De Bruyne
چکیده

Pressure wire-based fractional flow reserve is considered the standard of reference for evaluation of the ischemic potential of coronary stenoses and the expected benefit from revascularization. Accordingly, its application in daily practice or for research purposes has to be as standardized as possible to avoid technical or operator-related artifacts in pressure recordings. This document proposes a standardized way of acquiring, recording, interpreting, and archiving the pressure tracings for daily practice and for the purpose of clinical research involving a core laboratory. Proposed standardized steps enhance the uniformity of clinical practices and data interpretation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary physiology revisited : practical insights from the cardiac catheterization laboratory.

Various coronary physiological measurements can be made in the cardiac catheterization laboratory using sensor-tipped guidewires; they include the measurement of poststenotic absolute coronary flow reserve, the relative coronary flow reserve, and the pressure-derived fractional flow reserve of the myocardium. Ambiguity regarding abnormal microcirculation has been reduced or eliminated with meas...

متن کامل

Validation With Positron Emission Tomography

Background Experimental studies have shown that fractional flow reserve (defined as the ratio of maximal achievable flow in a stenotic area to normal maximal achievable flow) can be calculated from coronary pressure measurements only. The objectives of this study were to validate fractional flow reserve calculation in humans and to compare this information with that derived from quantitative co...

متن کامل

Hybrid Instantaneous Wave-Free Ratio–Fractional Flow Reserve versus Fractional Flow Reserve in the Real World

BACKGROUND The instantaneous wave-free ratio (iFR) is a novel method to assess the ischemic potential of coronary artery stenoses. Clinical trial data have shown that iFR has acceptable diagnostic agreement with fractional flow reserve (FFR), the reference standard for the functional assessment of coronary stenoses. This study compares iFR measurements with FFR measurements in a real world, sin...

متن کامل

Reproducibility of phase-contrast MRI in the coronary artery: towards noninvasive pressure gradient measurement and quantification of fractional flow reserve

Background Fractional Flow Reserve (FFR) is an invasively determined index of the functional severity of an intermediate coronary stenosis by measuring the pressure drop across the lesion [1]. Noninvasive pressure gradient (ΔP) measurements using phase-contrast (PC)-MRI have been attempted in the aorta, carotid, and renal arteries [2-4]. The purpose of this study is to assess the reproducibilit...

متن کامل

Impact of Right Atrial Pressure on Fractional Flow Reserve Measurements: Comparison of Fractional Flow Reserve and Myocardial Fractional Flow Reserve in 1,600 Coronary Stenoses.

OBJECTIVES This study sought to assess the impact of a wide range of mean right atrial pressure (Pra) on fractional flow reserve (FFR) measurements. BACKGROUND FFR invasively assesses the ischemic potential of coronary stenoses. FFR is calculated as the ratio of mean distal coronary pressure (Pd) to mean aortic pressure (Pa) during maximal hyperemia. The Pra is considered to have little impac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 68 7  شماره 

صفحات  -

تاریخ انتشار 2016