Electron microscopic analysis of biofilm on endotracheal tubes removed from intubated neonates.

نویسندگان

  • Karen B Zur
  • David L Mandell
  • Ronald E Gordon
  • Ian Holzman
  • Michael A Rothschild
چکیده

OBJECTIVES To determine if the phenomenon of biofilm accumulation and associated microbial colonization occurs on the surface of endotracheal tubes in the region of the subglottis in neonates. METHODS Endotracheal tubes removed from 9 consecutive neonatal patients intubated for more than 12 hours were processed (range, 13 hours to 8 days). A sterile control tube was also processed. For each, the portion of the endotracheal tube that had been in contact with the subglottis was determined using a previously published nomogram. A 1-cm-long cross-sectional segment of the endotracheal tube corresponding to the level of the subglottis was divided into 2 portions for both electron microscopy and aerobic/anaerobic cultures. RESULTS Two of 9 (22%) luminal surface cultures grew Staphylococcus species, 1 (11%) grew normal flora, and 6 (66%) had no growth. Three of 9 (33%) outer-surface cultures grew Staphylococcus species, 1 (11%) had gram-negative rods on staining but a sterile culture, and one enterococcal contaminant was found. Electron microscopy revealed that 8 of 9 inner lumen surfaces harbored bacteria and biofilm formation. All outer lumen surfaces had biofilm formation; 6 of 9 had bacterial colonization. There was no obvious difference in the appearance of the inner and outer tube surface accretions. No time-dependent differences were noted except of the longest indwelling tube (8 days). CONCLUSION This study demonstrates for the first time the presence of biofilm on the outer surface of neonatal endotracheal tubes. The data suggest that the presence of bacteria and/or biofilm does not correlate with other traditional indicators of microbial colonization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of Lateral and Supine Position on Bacterial Colonization of Endotracheal Tube in Neonates Admitted to Neonatal Intensive Care Unit

OBJECTIVE Recent data suggest that during mechanical ventilation, lateral patient position (in which the endotracheal tube is horizontal) decreases the incidence of bacterial colonization of ventilated neonates. The objective of this study was to evaluate the influence of lateral and supine position on bacterial colonization of endotracheal tube in neonates. METHODS We conducted a prospective...

متن کامل

Silver-coated endotracheal tubes and incidence of ventilator-associated pneumonia: the NASCENT randomized trial.

CONTEXT Ventilator-associated pneumonia (VAP) causes substantial morbidity. A silver-coated endotracheal tube has been designed to reduce VAP incidence by preventing bacterial colonization and biofilm formation. OBJECTIVE To determine whether a silver-coated endotracheal tube would reduce the incidence of microbiologically confirmed VAP. DESIGN, SETTING, AND PARTICIPANTS Prospective, random...

متن کامل

Description and microbiology of endotracheal tube biofilm in mechanically ventilated subjects.

BACKGROUND A biofilm is found on the inner side of endotracheal tubes (ETT) in mechanically ventilated patients, but its features and role in pneumonia remain unclear. METHODS This prospective, observational, monocentric study included critically ill ventilated subjects. Measurement of the ETT inner volume was first performed before extubation using the acoustic reflection method. After extub...

متن کامل

Endotracheal tubes coated with antiseptics decrease bacterial colonization of the ventilator circuits, lungs, and endotracheal tube.

BACKGROUND Formation of a bacterial biofilm within the endotracheal tube (ETT) after tracheal intubation is rapid and represents a ready source of lung bacterial colonization. The authors investigated bacterial colonization of the ventilator circuit, the ETT, and the lungs when the ETT was coated with silver-sulfadiazine and chlorhexidine in polyurethane, using no bacterial/viral filter attache...

متن کامل

Cost-effectiveness analysis of a silver-coated endotracheal tube to reduce the incidence of ventilator-associated pneumonia.

OBJECTIVE To conduct a cost-effectiveness analysis of the economic outcomes of ventilator-associated pneumonia (VAP) prevention associated with silver-coated endotracheal tubes versus uncoated endotracheal tubes. DESIGN We used a simple decision model based on a hypothetical 1,000-patient cohort intubated with silver-coated or uncoated endotracheal tubes. The primary end point was marginal ho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery

دوره 130 4  شماره 

صفحات  -

تاریخ انتشار 2004