Prediction of Refractive Error in Combined Vitrectomy and Cataract Surgery With One-Piece Acrylic Intraocular Lens
نویسندگان
چکیده
PURPOSE To compare the predicted and actual refractive errors of hydrophilic, one-piece, C-flex 570C (C-flex) intraocular lens (IOL) implantation in simultaneous vitrectomy and lens extraction in various conditions. METHODS One hundred fifty-nine eyes of patients who had lens extraction between March 2004 and September 2005 were enrolled in a retrospective study. Group 1 had lens extraction and IOL implantation, and Group 2 had lens extraction and IOL implantation with vitrectomy. IOL calculation was done with axial length and keratometry measurements. The actual and predicted refractive errors were compared at 1 and 6 months postoperatively. The factors influencing the postoperative refractive outcomes were analyzed. RESULTS The mean refractive predictive error (i.e., the actual minus predicted spherical equivalent) was +0.19+/-0.39 D (Diopter) and -0.26+/-0.45 D at 1 and 6 months postoperatively (all: p<0.001) in group 1, and -0.22+/-0.39 D and -0.06+/-0.62 D at 1 and 6 months postoperatively (p=0.013, p=0.399 respectively). In group 2, all surgical factors related to refractive errors were not statistically significant (all: p>0.05). CONCLUSIONS Refractive errors in combined surgery showed myopic shift of -0.50 D and -0.32 D at 1 and 6 months postoperatively compared with C-flex IOL implantation alone. With the hyperopic tendency of IOL and myopic tendency of vitrectomy, the combined surgery made postoperative refractive errors near emmetropia.
منابع مشابه
Prediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملASCRS white paper. Hydrophobic acrylic intraocular lenses in children.
After Sir Harold Ridley’s invention of the intraocular lens (IOL) in 1949, Dr. Edward Epstein implanted an IOL in a 12-year-old aphakic child in 1952. However, implantation in pediatric eyes was slow to catch on as many early attempts at IOL implantation in children resulted in complications. These results have been attributed to a lack of awareness of the need for primary posterior capsulectom...
متن کاملVisual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملIntraocular Lens Power Estimation in Combined Phacoemulsification and Pars Plana Vitrectomy in Eyes with Epiretinal Membranes: A Case-Control Study
PURPOSE To evaluate the accuracy of postoperative refractive outcomes of combined phacovitrectomy for epiretinal membrane (ERM) in comparison to cataract surgery alone. MATERIALS AND METHODS Thirty-nine eyes that underwent combined phacovitrectomy with intraocular lens (IOL) implantation for cataract and ERM (combined surgery group) and 39 eyes that received phacoemulsification for cataract (...
متن کاملNeodymium:yttrium-aluminum garnet capsulotomy rates after combined cataract surgery with implantation of a 4% water content hydrophobic acrylic intraocular lens and vitrectomy
BACKGROUND The purpose of this study was to examine neodymium:yttrium-aluminum garnet (Nd:YAG) capsulotomy rates after combined cataract surgery with implantation of a three-piece 4% water content hydrophobic acrylic intraocular lens (X-70, Eternity®) and vitrectomy, and compare diabetic retinopathy with nondiabetic retinopathy. METHODS Nd:YAG capsulotomy rates were evaluated for 72 eyes of 7...
متن کامل